Evidence map›Paper›PMID 25585398›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2015

An adaptive displacement estimation algorithm for improved reconstruction of thermal strain.

Xuan Ding, Debaditya Dutta, Ahmed M Mahmoud, Bryan Tillman, Steven A Leers, Kang Kim

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.8field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Xuan Ding
Debaditya Dutta
Ahmed M Mahmoud
Bryan Tillman
Steven A Leers
Kang Kim
University of Pittsburgh Medical Center · US

Funding

Cardiovascular Bioengineering Training ProgramT32HL076124 · NHLBI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI SANJEEV G SHROFF · 2005 to 2026
$7.0M
Ultrasound-induced Thermal Strain Imaging for Arterial Plaque CharacterizationR01HL098230 · NHLBI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI KIM, KANG · 2010 to 2014
$1.8M
High-resolution ultrasound in-vivo animal imaging system-Vevo2100S10RR027383 · NCRR · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI KIM, KANG · 2010 to 2010
$498k
NCRR NIH HHS 1S10RR027383NCRR NIH HHS S10 RR027383NHLBI NIH HHS 5R01HL098320NHLBI NIH HHS 5T32HL076124NHLBI NIH HHS R01 HL098230NHLBI NIH HHS T32 HL076124
6 · The paper itself

Abstract

Thermal strain imaging (TSI) can be used to differentiate between lipid and water-based tissues in atherosclerotic arteries. However, detecting small lipid pools in vivo requires accurate and robust displacement estimation over a wide range of displacement magnitudes. Phase-shift estimators such as Loupas' estimator and time-shift estimators such as normalized cross-correlation (NXcorr) are commonly used to track tissue displacements. However, Loupas' estimator is limited by phase-wrapping and NXcorr performs poorly when the SNR is low. In this paper, we present an adaptive displacement estimation algorithm that combines both Loupas' estimator and NXcorr. We evaluated this algorithm using computer simulations and an ex vivo human tissue sample. Using 1-D simulation studies, we showed that when the displacement magnitude induced by thermal strain was >λ/8 and the electronic system SNR was >25.5 dB, the NXcorr displacement estimate was less biased than the estimate found using Loupas' estimator. On the other hand, when the displacement magnitude was ≤λ/4 and the electronic system SNR was ≤25.5 dB, Loupas' estimator had less variance than NXcorr. We used these findings to design an adaptive displacement estimation algorithm. Computer simulations of TSI showed that the adaptive displacement estimator was less biased than either Loupas' estimator or NXcorr. Strain reconstructed from the adaptive displacement estimates improved the strain SNR by 43.7 to 350% and the spatial accuracy by 1.2 to 23.0% (P < 0.001). An ex vivo human tissue study provided results that were comparable to computer simulations. The results of this study showed that a novel displacement estimation algorithm, which combines two different displacement estimators, yielded improved displacement estimation and resulted in improved strain reconstruction.

Indexed as

AlgorithmsBiophysical PhenomenaFemoral ArteryHumansImage Processing, Computer-AssistedModels, BiologicalSignal-To-Noise RatioTemperatureUltrasonography

Identifiers

PMID25585398
PMCPMC4295651
OpenAlexW2086119845

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.