Evidence map›Paper›PMID 25575245›Full record

SynthesisThe Cochrane database of systematic reviews2015

Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization.

Patrick Brass, Martin Hellmich, Laurentius Kolodziej, Guido Schick, Andrew F Smith

2 registry-linked trialsOpen access · greenAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 122 papers, 19 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
122citing papers in PubMed, 19 pooled it
43.0field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02741453 nacompletednot on this mapstarted 2016, after this paper: background citation

Scanning of Bilateral Internal Jugular Veins With Ultrasound Prior to CVC Placement - Effect on Success and Complications

TypeinterventionalSponsorVanderbilt University Medical CenterRan2016 to 2017Enrolled278ConditionsCentral Venous Catheterization, Ultrasonography, Critical CareArmsStandard Practice, Bilateral IJ Ultrasound Scanning
NCT03741946 nacompletednot on this mapstarted 2018, after this paper: background citation

The Effect of Contralateral Head Rotation on Internal Jugular Vein to Carotid Artery Distance and Overlap Ratio

TypeinterventionalSponsorIndonesia UniversityRan2018 to 2019Enrolled34ConditionsCentral Venous Catheterization, SurgeryArmsTriangle of Sedillot identification using ultrasonography
3 · Its place in the literature

Who cites it

122 citing papers in PubMed, 19 syntheses or guidelines pooled it, 318 citations in OpenAlex.

  1. Guideline
  2. Guideline
  3. Pooled it
  4. [Clinical Practice and Quality Control Guidelines for Totally Implantable Venous Access Ports in Cancer Patients (2024)].Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition · 2025
    Guideline
  5. Pooled it
  6. Pooled it
  7. Ultrasound-guided arterial cannulation in the paediatric population.The Cochrane database of systematic reviews · 2023
    Pooled it
  8. Pooled it
  9. Pooled it
  10. Pooled it
  11. Pooled it
  12. Pooled it
  13. Pooled it
  14. Pooled it
  15. Ultrasound guidance for femoral venous access in electrophysiology procedures-systematic review and meta-analysis.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2020
    Pooled it
  16. Pooled it
  17. Guideline
  18. Pooled it
  19. Guideline
  20. Trial

62 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 2 countries.

Patrick BrassDepartment of Anaesthesiology, Intensive Care Medicine, and Pain Therapy, Helios Klinikum Krefeld, Lutherplatz 40, Krefeld, Germany, 47805.
Martin Hellmich
Laurentius Kolodziej
Guido Schick
Andrew F Smith
Essen University Hospital · DERoyal Lancaster Infirmary · GBUniversity of Cologne · DEWitten/Herdecke University · DE

Funding

Department of Health 10/4001/04
6 · The paper itself

Abstract

backgroundCentral venous catheters can help with diagnosis and treatment of the critically ill. The catheter may be placed in a large vein in the neck (internal jugular vein), upper chest (subclavian vein) or groin (femoral vein). Whilst this is beneficial overall, inserting the catheter risks arterial puncture and other complications and should be performed in as few attempts as possible.In the past, anatomical 'landmarks' on the body surface were used to find the correct place to insert these catheters, but ultrasound imaging is now available. A Doppler mode is sometimes used to supplement plain 'two-dimensional' ultrasound.

objectivesThe primary objective of this review was to evaluate the effectiveness and safety of two-dimensional ultrasound (US)- or Doppler ultrasound (USD)-guided puncture techniques for subclavian vein, axillary vein and femoral vein puncture during central venous catheter insertion in adults and children. We assessed whether there was a difference in complication rates between traditional landmark-guided and any ultrasound-guided central vein puncture.When possible, we also assessed the following secondary objectives: whether a possible difference could be verified with use of the US technique versus the USD technique; whether there was a difference between using ultrasound throughout the puncture ('direct') and using it only to identify and mark the vein before starting the puncture procedure ('indirect'); and whether these possible differences might be evident in different groups of patients or with different levels of experience among those inserting the catheters. SEARCH

methodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL) (2013, Issue 1), MEDLINE (1966 to 15 January 2013), EMBASE (1966 to 15 January 2013), the Cumulative Index to Nursing and Allied Health Literature (CINAHL) (1982 to 15 January 2013), reference lists of articles, 'grey literature' and dissertations. An additional handsearch focused on intensive care and anaesthesia journals and abstracts and proceedings of scientific meetings. We attempted to identify unpublished or ongoing studies by contacting companies and experts in the field, and we searched trial registers. We reran the search in August 2014. We will deal with any studies of interest when we update the review. SELECTION CRITERIA: Randomized and quasi-randomized controlled trials comparing two-dimensional ultrasound or Doppler ultrasound versus an anatomical 'landmark' technique during insertion of subclavian or femoral venous catheters in both adults and children. DATA COLLECTION AND ANALYSIS: Three review authors independently extracted data on methodological quality, participants, interventions and outcomes of interest using a standardized form. We performed a priori subgroup analyses. MAIN

resultsAltogether 13 studies enrolling 2341 participants (and involving 2360 procedures) fulfilled the inclusion criteria. The quality of evidence was very low (subclavian vein N = 3) or low (subclavian vein N = 4, femoral vein N = 2) for most outcomes, moderate for one outcome (femoral vein) and high at best for two outcomes (subclavian vein N = 1, femoral vein N = 1). Most of the trials had unclear risk of bias across the six domains, and heterogeneity among the studies was significant.For the subclavian vein (nine studies, 2030 participants, 2049 procedures), two-dimensional ultrasound reduced the risk of inadvertent arterial puncture (three trials, 498 participants, risk ratio (RR) 0.21, 95% confidence interval (CI) 0.06 to 0.82; P value 0.02, I² = 0%) and haematoma formation (three trials, 498 participants, RR 0.26, 95% CI 0.09 to 0.76; P value 0.01, I² = 0%). No evidence was found of a difference in total or other complications (together, US, USD), overall (together, US, USD), number of attempts until success (US) or first-time (US) success rates or time taken to insert the catheter (US).For the femoral vein, fewer data were available for analysis (four studies, 311 participants, 311 procedures). No evidence was found of a difference in inadvertent arterial puncture or other complications. However, success on the first attempt was more likely with ultrasound (three trials, 224 participants, RR 1.73, 95% CI 1.34 to 2.22; P value < 0.0001, I² = 31%), and a small increase in the overall success rate was noted (RR 1.11, 95% CI 1.00 to 1.23; P value 0.06, I² = 50%). No data on mortality or participant-reported outcomes were provided. AUTHORS'

conclusionsOn the basis of available data, we conclude that two-dimensional ultrasound offers small gains in safety and quality when compared with an anatomical landmark technique for subclavian (arterial puncture, haematoma formation) or femoral vein (success on the first attempt) cannulation for central vein catheterization. Data on insertion by inexperienced or experienced users, or on patients at high risk for complications, are lacking. The results for Doppler ultrasound techniques versus anatomical landmark techniques are uncertain.

Indexed as

Femoral VeinSubclavian VeinUltrasonography, InterventionalAdultAnatomic LandmarksCatheterization, Central VenousChildCritical IllnessHumansPuncturesRandomized Controlled Trials as Topic

Identifiers

PMID25575245
PMCPMC6516998
OpenAlexW1627317253

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.