Evidence map›Paper›PMID 25574449›Full record

ArticleBiomedical optics express2014

Digitally synthesized beat frequency-multiplexed fluorescence lifetime spectroscopy.

Jacky C K Chan, Eric D Diebold, Brandon W Buckley, Sien Mao, Najva Akbari, Bahram Jalali

Abstract read
In one paragraph

Article in Biomedical optics express, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jacky C K ChanDepartments of Electrical Engineering, University of California, Los Angeles, CA 90095, USA.
Eric D DieboldDepartments of Electrical Engineering, University of California, Los Angeles, CA 90095, USA ; Department of Bioengineering, University of California, Los Angeles, CA 90095, USA.
Brandon W BuckleyDepartments of Electrical Engineering, University of California, Los Angeles, CA 90095, USA.
Sien MaoDepartments of Electrical Engineering, University of California, Los Angeles, CA 90095, USA.
Najva AkbariDepartments of Electrical Engineering, University of California, Los Angeles, CA 90095, USA.
Bahram JalaliDepartments of Electrical Engineering, University of California, Los Angeles, CA 90095, USA ; Department of Bioengineering, University of California, Los Angeles, CA 90095, USA ; Department of Surgery, David Geffen School of Medicine, University of California, Los Angeles, CA 90095, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Frequency domain fluorescence lifetime imaging is a powerful technique that enables the observation of subtle changes in the molecular environment of a fluorescent probe. This technique works by measuring the phase delay between the optical emission and excitation of fluorophores as a function of modulation frequency. However, high-resolution measurements are time consuming, as the excitation modulation frequency must be swept, and faster low-resolution measurements at a single frequency are prone to large errors. Here, we present a low cost optical system for applications in real-time confocal lifetime imaging, which measures the phase vs. frequency spectrum without sweeping. Deemed Lifetime Imaging using Frequency-multiplexed Excitation (LIFE), this technique uses a digitally-synthesized radio frequency comb to drive an acousto-optic deflector, operated in a cat's-eye configuration, to produce a single laser excitation beam modulated at multiple beat frequencies. We demonstrate simultaneous fluorescence lifetime measurements at 10 frequencies over a bandwidth of 48 MHz, enabling high speed frequency domain lifetime analysis of single- and multi-component sample mixtures.

Indexed as

(170.1065) Acousto-optics(170.1790) Confocal microscopy(170.2520) Fluorescence microscopy(170.3650) Lifetime-based sensing

Identifiers

PMID25574449
PMCPMC4285616

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.