Evidence map›Paper›PMID 25569757›Full record

ArticleSensors (Basel, Switzerland)2015

A multi-channel, flex-rigid ECoG microelectrode array for visual cortical interfacing.

Elena Tolstosheeva, Víctor Gordillo-González, Volker Biefeld, Ludger Kempen, Sunita Mandon, Andreas K Kreiter, Walter Lang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Elena TolstosheevaInstitute for Microsensors, Actuators and Systems (IMSAS), Microsystems Center Bremen (MCB), University of Bremen, Bremen 28359, Germany. et@imsas.uni-bremen.de.
Víctor Gordillo-GonzálezInstitute for Brain Research, Center for Cognitive Sciences, University of Bremen, Bremen 28359, Germany. gordillo@brain.uni-bremen.de.
Volker BiefeldInstitute for Microsensors, Actuators and Systems (IMSAS), Microsystems Center Bremen (MCB), University of Bremen, Bremen 28359, Germany. vbiefeld@imsas.uni-bremen.de.
Ludger KempenInstitute for Microsensors, Actuators and Systems (IMSAS), Microsystems Center Bremen (MCB), University of Bremen, Bremen 28359, Germany. lkempen@imsas.uni-bremen.de.
Sunita MandonInstitute for Brain Research, Center for Cognitive Sciences, University of Bremen, Bremen 28359, Germany. mandon@brain.uni-bremen.de.
Andreas K KreiterInstitute for Brain Research, Center for Cognitive Sciences, University of Bremen, Bremen 28359, Germany. kreiter@brain.uni-bremen.de.
Walter LangInstitute for Microsensors, Actuators and Systems (IMSAS), Microsystems Center Bremen (MCB), University of Bremen, Bremen 28359, Germany. wlang@imsas.uni-bremen.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

High-density electrocortical (ECoG) microelectrode arrays are promising signal-acquisition platforms for brain-computer interfaces envisioned, e.g., as high-performance communication solutions for paralyzed persons. We propose a multi-channel microelectrode array capable of recording ECoG field potentials with high spatial resolution. The proposed array is of a 150 mm2 total recording area; it has 124 circular electrodes (100, 300 and 500 µm in diameter) situated on the edges of concentric hexagons (min. 0.8 mm interdistance) and a skull-facing reference electrode (2.5 mm2 surface area). The array is processed as a free-standing device to enable monolithic integration of a rigid interposer, designed for soldering of fine-pitch SMD-connectors on a minimal assembly area. Electrochemical characterization revealed distinct impedance spectral bands for the 100, 300 and 500 µm-type electrodes, and for the array's own reference. Epidural recordings from the primary visual cortex (V1) of an awake Rhesus macaque showed natural electrophysiological signals and clear responses to standard visual stimulation. The ECoG electrodes of larger surface area recorded signals with greater spectral power in the gamma band, while the skull-facing reference electrode provided higher average gamma power spectral density (γPSD) than the common average referencing technique.

Indexed as

Brain-Computer InterfacesMicroelectrodesAnimalsDielectric SpectroscopyElectroencephalographyElectrophysiological PhenomenaMacaca mulattaMicrotechnologySignal Processing, Computer-AssistedSodium ChlorideTime FactorsVisual CortexSodium Chloride

Identifiers

PMID25569757
PMCPMC4327052

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.