Evidence map›Paper›PMID 25568143›Full record

ArticleJournal of diabetes science and technology2015

The impact of measurement frequency on the domains of glycemic control in the critically ill--a Monte Carlo simulation.

James S Krinsley, David E Bruns, James C Boyd

Abstract read
In one paragraph

Article in Journal of diabetes science and technology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Trial
  4. Review
  5. Observational
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Facilitators and Barriers to Nursing Implementation of Continuous Glucose Monitoring (CGM) in Critically Ill Patients With COVID-19.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2021
    Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Review
  17. Review
  18. Untangling glycaemia and mortality in critical care.Critical care (London, England) · 2017
    Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

James S KrinsleyDivision of Critical Care, Stamford Hospital, Stamford, CT, USA Columbia University College of Physicians and Surgeons, New York, NY, USA jkrinsley@stamhealth.org.
David E BrunsDepartment of Pathology, University of Virginia, Charlottesville VA, USA.
James C BoydDepartment of Pathology, University of Virginia, Charlottesville VA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The role of blood glucose (BG) measurement frequency on the domains of glycemic control is not well defined. This Monte Carlo mathematical simulation of glycemic control in a cohort of critically ill patients modeled sets of 100 patients with simulated BG-measuring devices having 5 levels of measurement imprecision, using 2 published insulin infusion protocols, for 200 hours, with 3 different BG-measurement intervals-15 minutes (Q15'), 1 hour (Q1h), and 2 hours (Q2h)-resulting in 1,100,000 BG measurements for 3000 simulated patients. The model varied insulin sensitivity, initial BG value and rate of gluconeogenesis. The primary outcomes included rates of hyperglycemia (BG > 180 mg/dL), hypoglycemia (BG < 70 and 40 mg/dL), proportion of patients with elevated glucose variability (within-patient coefficient of variation [CV] > 20%), and time in range (BG ranges 80-150 mg/dL and 80-180 mg/dL). Percentages of hyperglycemia, hypoglycemia at both thresholds, and patients with elevated glucose variability as well as time outside glycemic targets were substantially higher in simulations with measurement interval Q2h compared to those with measurement interval Q1h and moderately higher in simulations with Q1h than in those with Q15'. Higher measurement frequency mitigated the deleterious effect of high measurement imprecision, defined as CV ≥ 15%. This Monte Carlo simulation suggests that glycemic control in critically ill patients is more optimal with a BG measurement interval no longer than 1h, with further benefit obtained with use of measurement interval of 15'. These findings have important implications for the development of glycemic control standards.

Indexed as

Monte Carlo MethodBlood GlucoseCritical IllnessDiabetes MellitusHumansHyperglycemiaHypoglycemiaBlood Glucoseblood glucosecritically illglucose variabilityhyperglycemiahypoglycemiamonitoring frequencyMonte Carlo simulationtime in range

Identifiers

PMID25568143
PMCPMC4604588

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.