ArticleJournal of craniovertebral junction & spine2014
Optimal measurement for "posterolateral protrusion" of the vertebral artery at the craniovertebral junction using computed tomography angiography.
Article in Journal of craniovertebral junction & spine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 4 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeAmong extraosseous abnormalities of the vertebral artery (VA) at the craniovertebral junction (CVJ), available evidence regarding "posterolateral protrusion," the VA running distant from the groove over the superior surface of the posterior arch of the atlas, is limited. The purpose of this study was to determine the optimal measurement to indicate posterolateral protrusion of the VA. MATERIALS AND
methodsComputed tomography angiography (CTA) images of 40 consecutive patients with cervical disease were reviewed. Ultimately, 66 arteries were included in this study. Five parameters predicted to indicate posterolateral protrusion of the VA were defined (A-E) and measured by two surgeons twice over a 2-week interval. Intraclass correlation coefficients (ICC) were used to examine intra-observer reproducibility and inter-observer reliability. Receiver operating characteristic (ROC) curve analysis was performed to determine the most optimal parameter to predict posterolateral protrusion of the VA.
resultsExcellent inter-observer reliability and intra-observer reproducibility were obtained for all parameters (ICC = 0.87-0.99). Among them, parameter A, defined as the maximal length from the outer surface of the VA to the outer surface of the posterior arch of the atlas, was most accurately described posterolateral protrusion of the VA. The optimal cut-off value of parameter A obtained with ROC curves was 8.3 mm (sensitivity 97.5%, specificity 100%).
conclusionsThe measurement in this study can quantitatively evaluate the posterolateral protrusion of the VA. Before posterior surgery at the CVJ, pre-operative CTA can help surgeons detect anomalous VA and reduce the risk of intra-operative VA injury.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.