Evidence map›Paper›PMID 25546853›Full record

ArticleIEEE transactions on bio-medical engineering2015

Microbubbles and blood-brain barrier opening: a numerical study on acoustic emissions and wall stress predictions.

Nazanin Hosseinkhah, David E Goertz, Kullervo Hynynen

Abstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Review
  15. Review
  16. Therapeutic Potentials of Localized Blood-Brain Barrier Disruption by Noninvasive Transcranial Focused Ultrasound: A Technical Review.Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society · 2020
    Review
  17. Article
  18. Review
  19. Review
  20. MRI-Guided Focused Ultrasound for Targeted Delivery of rAAV to the Brain.Methods in molecular biology (Clifton, N.J.) · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Nazanin Hosseinkhah
David E Goertz
Kullervo Hynynen

Funding

Ultrasound Therapy Delivery Through Intact SkullR01EB003268 · NIBIB · SUNNYBROOK & WOMEN'S COLL HLTH SCIS CTR · PI HYNYNEN, KULLERVO · 2003 to 2020
$8.2M
NIBIB NIH HHS EB003268NIBIB NIH HHS R01 EB003268
6 · The paper itself

Abstract

Focused ultrasound with microbubbles is an emerging technique for blood-brain barrier opening. Here, a comprehensive theoretical model of a bubble-fluid-vessel system has been developed which accounts for the bubble's nonspherical oscillations inside a microvessel, and its resulting acoustic emissions. Numerical simulations of unbound and confined encapsulated bubbles were performed to evaluate the effect of the vessel wall on acoustic emissions and vessel wall stresses. Using a Marmottant shell model, the normalized second harmonic to fundamental emissions first decreased as a function of pressure (>50 kPa) until reaching a minima ("transition point") at which point they increased. The transition point of unbound compared to confined bubble populations occurred at different pressures and was associated with an accompanying increase in shear and circumferential wall stresses. As the wall stresses depend on the bubble to vessel wall distance, the stresses were evaluated for bubbles with their wall at a constant distance to a flat wall. As a result, the wall stresses were bubble size and frequency dependent and the peak stress values induced by bubbles larger than resonance remained constant versus frequency at a constant mechanical index.

Indexed as

MicrobubblesModels, CardiovascularAcousticsBiomechanical PhenomenaBlood-Brain BarrierComputer SimulationFinite Element AnalysisHumansMicrovesselsPressureSignal Processing, Computer-AssistedUltrasonography

Identifiers

PMID25546853
PMCPMC4406873

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.