Evidence map›Paper›PMID 25544948›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2014

Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy:

Michael T Tomkowiak, Amish N Raval, Michael S Van Lysel, Tobias Funk, Michael A Speidel

Abstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Localization of cardiac volume and patient features in inverse geometry x-ray fluoroscopy.Proceedings of SPIE--the International Society for Optical Engineering · 2017
    Article
  2. Single-view geometric calibration for C-arm inverse geometry CT.Journal of medical imaging (Bellingham, Wash.) · 2017
    Article
  3. A geometric calibration method for inverse geometry computed tomography using P-matrices.Proceedings of SPIE--the International Society for Optical Engineering · 2016
    Article
  4. Article
  5. Detector, collimator and real-time reconstructor for a new scanning-beam digital x-ray (SBDX) prototype.Proceedings of SPIE--the International Society for Optical Engineering
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Michael T TomkowiakUniversity of Wisconsin-Madison, Department of Medical Physics, 1111 Highland Ave, Madison, Wisconsin 53705, United States.
Amish N RavalUniversity of Wisconsin-Madison, Department of Medicine, 600 Highland Ave, Madison, Wisconsin 53792, United States.
Michael S Van LyselUniversity of Wisconsin-Madison, Department of Medical Physics, 1111 Highland Ave, Madison, Wisconsin 53705, United States ; University of Wisconsin-Madison, Department of Medicine, 600 Highland Ave, Madison, Wisconsin 53792, United States.
Tobias FunkTriple Ring Technologies, Inc., 39655 Eureka Dr, Newark, California 94560, United States.
Michael A SpeidelUniversity of Wisconsin-Madison, Department of Medical Physics, 1111 Highland Ave, Madison, Wisconsin 53705, United States ; University of Wisconsin-Madison, Department of Medicine, 600 Highland Ave, Madison, Wisconsin 53792, United States.

Funding

Low-Dose Tomosynthetic Interventional System For Quantitative Cardiac ImagingR01HL084022 · NHLBI · UNIVERSITY OF WISCONSIN-MADISON · PI SPEIDEL, MICHAEL A · 2007 to 2015
$4.4M
NHLBI NIH HHS R01 HL084022
6 · The paper itself

Abstract

Proper sizing of interventional devices to match coronary vessel dimensions improves procedural efficiency and therapeutic outcomes. We have developed a method that uses an inverse geometry x-ray fluoroscopy system [scanning beam digital x-ray (SBDX)] to automatically determine vessel dimensions from angiograms without the need for magnification calibration or optimal views. For each frame period (1/15th of a second), SBDX acquires a sequence of narrow beam projections and performs digital tomosynthesis at multiple plane positions. A three-dimensional model of the vessel is reconstructed by localizing the depth of the vessel edges from the tomosynthesis images, and the model is used to calculate the length and diameter in units of millimeters. The

Indexed as

cardiac interventionsinverse geometryquantitative coronary angiographyx-ray fluoroscopy

Identifiers

PMID25544948
PMCPMC4275130

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.