Evidence map›Paper›PMID 25540709›Full record

ArticleInternational journal of sports physical therapy2014

Reliability of and the relationship between ultrasound measurement and three clinical assessments of humeral torsion.

Rebecca Feuerherd, Mark A Sutherlin, Joseph M Hart, Susan A Saliba

Open access · greenAbstract read
In one paragraph

Article in International journal of sports physical therapy, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.6field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. ASSESSMENT OF HUMERAL TORSION BY PALPATION IN BASEBALL PITCHERS: A VALIDATION STUDY.International journal of sports physical therapy · 2020
    Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Rebecca FeuerherdActive Edge Wellness Center, West Linn, OR.
Mark A SutherlinUniversity of Virginia, Charlottesville, VA.
Joseph M HartUniversity of Virginia, Charlottesville, VA.
Susan A SalibaUniversity of Virginia, Charlottesville, VA.
University of Virginia · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

PURPOSE/

backgroundDifferences in humeral torsion have been observed between overhead athletes and non-athletes. Although humeral torsion may be an adaptive process for athletic performance, it may be associated with injury. Methods for measuring humeral torsion have consisted of radiography, computer tomography, and ultrasound imaging. However, diagnostic imaging may be costly and not available to all clinicians. The implementation of clinical assessments may be an alternative way to measure humeral torsion. Before clinical measures can be recommended, these assessments need to be evaluated for validity and reliability of each test. The purpose of this study was to assess the intratester and intertester reliability of three clinical tests, intratester reliability of ultrasound measures, and the validity of each clinical test to ultrasound measures.

methodsThirty participants (male: 12, female: 18; age: 20±2 years; height: 174.24±9.35 cm; mass: 70.53±11.06 kg; body mass index: 23.13±2.47 kg/m(2); years in sport: 9±4 years) with experience in overhead sports were assessed for humeral torsion, bilaterally. Humeral torsion was assessed using musculoskeletal ultrasound by a single assessor, and using three separate clinical assessments by two independent assessors. Clinical assessments included the angle of rotation during both the bicipital tuberosity palpation with the shoulder abducted at 90 degrees (Palp90) or 45 degrees (Palp45), and the angle of external rotation during horizontal adduction (HADD).

resultsIntratester reliability for the ultrasound measure was good (ICC=0.907), along with intratester reliability for both assessors across each clinical assessment (ICC's > 0.769). Poor to moderate reliability was observed between assessors for each clinical assessment (ICC=0.256 Palp90, ICC=0.419 Palp45, ICC=0.243 HADD. Only the Palp90 measure had a fair but significant (r=0.326, p=0.011) relationship with ultrasound measures.

conclusionIndividual assessors can achieve reliable ultrasound, bicipital tuberosity palpation and HADD values across multiple trials; however, these measures are not consistent between assessors. Additionally, only one clinical test had a fair but significant relationship with ultrasound measures. Improved testing procedures may be needed to increase between assessor reliability and strength of relationships to ultrasound measures. Current application of clinical assessments to measure humeral torsion is limited. LEVEL OF EVIDENCE: 3b; Grade of Recommendation C.

Indexed as

athletesoverheadshoulder

Identifiers

PMID25540709
PMCPMC4275198
OpenAlexW194173966

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.