Evidence map›Paper›PMID 25540600›Full record

ArticleMedical devices (Auckland, N.Z.)2014

The Photodynamic Bone Stabilization System: a minimally invasive, percutaneous intramedullary polymeric osteosynthesis for simple and complex long bone fractures.

Paul Vegt, Jeffrey M Muir, Jon E Block

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Medical devices (Auckland, N.Z.), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04842266 (A Prospective Study of the IlluminOss Photodynamic Bone Stabilization System for the Treatment of Impending and Actual Pathological Fractures in the Pelvis From Metastatic Bone Disease or Geriatric Pelvic Fractures), which is not on this map. Cited by 21 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04842266 recruitingnot on this mapstarted 2021, after this paper: background citation

A Prospective Study of the IlluminOss Photodynamic Bone Stabilization System for the Treatment of Impending and Actual Pathological Fractures in the Pelvis From Metastatic Bone Disease or Geriatric Pelvic Fractures

TypeobservationalSponsorMassachusetts General HospitalRan2021 to 2027Enrolled100ConditionsCancer Metastatic, Trauma, Pathologic FractureArmsIlluminOss pelvic implant for oncologic indication, IlluminOss pelvic implant for geriatric trauma indication
3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 1 synthesis or guideline pooled it, 34 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Biomechanical Characterization of Metacarpal Fixation: Internal Load Determination and Evaluation of a Novel Adhesive Osteosynthesis.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025
    Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Outcome after treatment of distal radius fractures in the elderly using the IlluminOssEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society · 2021
    Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 2 countries.

Paul VegtDepartment of Surgery, Albert Schweitzer Hospital, Dordrecht, The Netherlands.
Jeffrey M MuirThe Jon Block Group, San Francisco, CA, USA.
Jon E BlockThe Jon Block Group, San Francisco, CA, USA.
Albert Schweitzer Hospital · GA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The treatment of osteoporotic long bone fractures is difficult due to diminished bone density and compromised biomechanical integrity. The majority of osteoporotic long bone fractures occur in the metaphyseal region, which poses additional problems for surgical repair due to increased intramedullary volume. Treatment with internal fixation using intramedullary nails or plating is associated with poor clinical outcomes in this patient population. Subsequent fractures and complications such as screw pull-out necessitate additional interventions, prolonging recovery and increasing health care costs. The Photodynamic Bone Stabilization System (PBSS) is a minimally invasive surgical technique that allows clinicians to repair bone fractures using a light-curable polymer contained within an inflatable balloon catheter, offering a new treatment option for osteoporotic long bone fractures. The unique polymer compound and catheter application provides a customizable solution for long bone fractures that produces internal stability while maintaining bone length, rotational alignment, and postsurgical mobility. The PBSS has been utilized in a case series of 41 fractures in 33 patients suffering osteoporotic long bone fractures. The initial results indicate that the use of the light-cured polymeric rod for this patient population provides excellent fixation and stability in compromised bone, with a superior complication profile. This paper describes the clinical uses, procedural details, indications for use, and the initial clinical findings of the PBSS.

Indexed as

bone densitylong bone fractureorthopaedicsosteoporosispolymeric rodsurgery

Identifiers

PMID25540600
PMCPMC4270358
OpenAlexW2040552164

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.