ArticleEuropean radiology2015
Low-dose biplanar radiography can be used in children and adolescents to accurately assess femoral and tibial torsion and greatly reduce irradiation.
Article in European radiology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- A simple maximum intensity projection method for measuring proximal femoral anteversion: An observer reliability study.Journal of experimental orthopaedics · 2026Article
- Assessment and management of torsional malalignment in paediatric patients with patellofemoral joint instability.Journal of children's orthopaedics · 2026Article
- Tin-filtered ultra-low-dose CT for lower limb torsion measurements in children and adolescents: a prospective study.Skeletal radiology · 2026Article
- Radiological assessment of lower limb torsional deformities: a narrative review.Annals of joint · 2025Review
- Lower limb maltorsion and acetabular deformity in children and adolescents with X-linked hypophosphatemia.Frontiers in endocrinology · 2024Article
- Rotational Osteotomy for Femoral Version/Tibial Torsion.Current reviews in musculoskeletal medicine · 2022Review
- Ultra-low-dose computed tomography for torsion measurements of the lower extremities in children and adolescents.Insights into imaging · 2022Article
- Comparison of clinical with CT based evaluation for tibial torsion.Journal of clinical orthopaedics and trauma · 2022Article
- Femoral and tibial torsion measurements based on EOS imaging compared to 3D CT reconstruction measurements.Annals of translational medicine · 2019Article
- Retrograde Intramedullary Nail Fixation for Derotational Femoral Osteotomy for Recurrent Femoropatellar Instability.Case reports in orthopedics · 2019Article
- Organ doses and lifetime attributable risk evaluations for scoliosis examinations of adolescent patients with the EOS imaging system.La Radiologia medica · 2018Article
- Assessment of two-dimensional (2D) and three-dimensional (3D) lower limb measurements in adults: Comparison of micro-dose and low-dose biplanar radiographs.European radiology · 2016Article
- Significant differences in femoral torsion values depending on the CT measurement technique.Archives of orthopaedic and trauma surgery · 2016Article
- Radiation dose of digital radiography (DR) versus micro-dose x-ray (EOS) on patients with adolescent idiopathic scoliosis: 2016 SOSORT- IRSSD "John Sevastic Award" Winner in Imaging Research.Scoliosis and spinal disorders · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo evaluate in children the agreement between femoral and tibial torsion measurements obtained with low-dose biplanar radiography (LDBR) and CT, and to study dose reduction ratio between these two techniques both in vitro and in vivo. MATERIALS AND
methodsThirty children with lower limb torsion abnormalities were included in a prospective study. Biplanar radiographs and CTs were performed for measurements of lower limb torsion on each patient. Values were compared using Bland-Altman plots. Interreader and intrareader agreements were evaluated by intraclass correlation coefficients. Comparative dosimetric study was performed using an ionization chamber in a tissue-equivalent phantom, and with thermoluminescent dosimeters in 5 patients.
resultsAverage differences between CT and LDBR measurements were -0.1° ±1.1 for femoral torsion and -0.7° ±1.4 for tibial torsion. Interreader agreement for LDBR measurements was very good for both femoral torsion (FT) (0.81) and tibial torsion (TT) (0.87). Intrareader agreement was excellent for FT (0.97) and TT (0.89). The ratio between CT scan dose and LDBR dose was 22 in vitro (absorbed dose) and 32 in vivo (skin dose).
conclusionLower limb torsion measurements obtained with LDBR are comparable to CT measurements in children and adolescents, with a considerably reduced radiation dose. KEY POINTS: • LDBR and CT lower-limb torsion measurements are comparable in children and adolescents. • LDBR considerably reduced radiation dose necessary for lower-limb torsion measurements. • LDBR can be used for evaluation of lower limb-torsion in orthopaediatric patients.
Indexed as
Identifiers
25533631What OpenQuestion holds
Registered trials