SynthesisBMC cardiovascular disorders2014
Ability of ambulatory ECG-based T-wave alternans to modify risk assessment of cardiac events: a systematic review.
Synthesis in BMC cardiovascular disorders, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 19 citations in OpenAlex.
- R1 Prognostic Significance of T-Wave Amplitude Variability for Adverse Cardiovascular Outcomes: A Systematic Review and Meta-Analysis.Journal of arrhythmia · 2026Article
- Enhancing Comprehensive Assessments in Chronic Heart Failure Caused by Ischemic Heart Disease: The Diagnostic Utility of Holter ECG Parameters.Medicina (Kaunas, Lithuania) · 2024Article
- JCS/JHRS 2022 Guideline on Diagnosis and Risk Assessment of Arrhythmia.Journal of arrhythmia · 2024Article
- T-Wave Analysis on the 24 h Holter ECG Monitoring as a Predictive Assessment of Major Adverse Cardiovascular Events in Patients with Myocardial Infarction: A Literature Review and Future Perspectives.Life (Basel, Switzerland) · 2023Review
- Electrophysiological Mechanisms Underlying T-Wave Alternans and Their Role in Arrhythmogenesis.Frontiers in physiology · 2021Review
- Increased Beat-to-Beat Variability of T-Wave Heterogeneity Measured From Standard 12-Lead Electrocardiogram Is Associated With Sudden Cardiac Death: A Case-Control Study.Frontiers in physiology · 2020Article
- ECG Parameters for Malignant Ventricular Arrhythmias: A Comprehensive Review.Journal of medical and biological engineering · 2017Review
- Microvolt T-wave Alternans: Where Are We Now?Arrhythmia & electrophysiology review · 2016Article
- George Ralph Mines (1886-1914): the dawn of cardiac nonlinear dynamics.The Journal of physiology · 2016Article
- Electrocardiographic Predictors of Cardiovascular Mortality.Disease markers · 2015Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundExercise-based spectral T-wave alternans (TWA) has been proposed as a noninvasive tool-identifying patients at risk of sudden cardiac death (SCD) and cardiac mortality. Prior studies have indicated that ambulatory electrocardiogram (AECG)-based TWA is an important alternative platform to exercise for risk stratification of cardiac events. This study sought to review data regarding 24-hour AECG-based TWA and to discuss its potential role in risk stratification of fatal cardiac events across a series of patient risk profiles.
methodsProspective clinical studies of the predictive value of AECG-based TWA obtained with daily activity published between January 1990 and November 2014 were retrieved. Major endpoints included composite endpoint of SCD, cardiac mortality, and severe arrhythmic events.
resultsData were accumulated from 5 studies involving a total of 1,588 patients, including 317 positive and 1,271 negative TWA results. Compared with the negative group, positive group showed increased rates of SCD (hazard ratio [HR]: 7.49, 95% confidence interval [CI]: 2.65 to 21.15), cardiac mortality (HR: 4.75, 95% CI: 0.42 to 53.55), and composite endpoint (SCD, cardiac mortality, and severe arrhythmic events, HR: 5.94, 95% CI: 1.80 to 19.63). For the 4 studies evaluating TWA measured using the modified moving average method, the HR associated with a positive versus negative TWA result was 9.51 (95% CI: 4.99 to 18.11) for the composite endpoint.
conclusionsThe positive group of AECG-based TWA has a nearly six-fold risk of severe outcomes compared with the negative group. Therefore, AECG-based TWA provides an accurate means of predicting fatal cardiac events.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.