Evidence map›Paper›PMID 25520416›Full record

ArticleThe Journal of bone and joint surgery. American volume2014

Distributed analysis of hip implants using six national and regional registries: comparing metal-on-metal with metal-on-highly cross-linked polyethylene bearings in cementless total hip arthroplasty in young patients.

Ove Furnes, Elizabeth Paxton, Guy Cafri, Stephen Graves, Barbara Bordini, Thomas Comfort, Moises Coll Rivas, Samprit Banerjee, Art Sedrakyan

Abstract readComparative Study
In one paragraph

Article in The Journal of bone and joint surgery. American volume, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
4.1field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 40 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Observational
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 7 institutions in 5 countries.

Ove FurnesThe Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Mollendalsbakken 11, N-5021 Bergen, Norway.
Elizabeth PaxtonSurgical Outcomes & Analysis Department, Kaiser Permanente, 8954 Rio San Diego Drive, Suite 406, San Diego, CA 92108.
Guy CafriSurgical Outcomes & Analysis Department, Kaiser Permanente, 8954 Rio San Diego Drive, Suite 406, San Diego, CA 92108.
Stephen GravesAustralia Orthopaedic Association National Joint Replacement Registry, Discipline of Public Health, MDP DX 650 511, University of Adelaide, Adelaide, SA 5005, Australia.
Barbara BordiniRegister of the Orthopaedic Prosthetic Implants (R.I.P.O. [Registro dell'implantologia Protesica Ortopedica]), c/o Medical Technology Laboratory, Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy.
Thomas ComfortHealthEast Joint Registry, 1690 University Avenue West, Data Science, Suite 400, Minneapolis, MN 55104.
Moises Coll RivasConsorci Sanitari del Maresme, Hospital de Mataro, Carretera de Cirera s/n, 08304 Mataro (Barcelona), Catalonia, Spain.
Samprit BanerjeeWeill Cornell Medical College, 402 East 67th Street, New York, NY 10065.
Art SedrakyanWeill Cornell Medical College, 402 East 67th Street, New York, NY 10065.
Cornell University · USKaiser Permanente San Diego Medical Center · USHaukeland University Hospital · NOHealthEast Care System · USHospital de Mataró · ESIstituto Ortopedico Rizzoli · ITUniversity of Adelaide · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe regulation of medical devices has attracted controversy recently because of problems related to metal-on-metal hip implants. There is growing evidence that metal-on-metal implants fail early and cause local and systemic complications. However, the failure associated with metal-on-metal head size is not consistently documented and needs to be communicated to patients and surgeons. The purpose of this study is to compare implant survival of metal on metal with that of metal on highly cross-linked polyethylene.

methodsUsing a distributed health data network, primary total hip arthroplasties were identified from six national and regional total joint arthroplasty registries (2001 to 2010). Inclusion criteria were patient age of forty-five to sixty-four years, cementless total hip arthroplasties, primary osteoarthritis diagnosis, and exclusion of the well-known outlier implant ASR (articular surface replacement). The primary outcome was revision for any reason. A meta-analysis of survival probabilities was performed with use of a fixed-effects model. Metal-on-metal implants with a large head size of >36 mm were compared with metal-on-highly cross-linked polyethylene implants.

resultsMetal-on-metal implants with a large head size of >36 mm were used in 5172 hips and metal-on-highly cross-linked polyethylene implants were used in 14,372 hips. Metal-on-metal total hip replacements with a large head size of >36 mm had an increased risk of revision compared with metal-on-highly cross-linked polyethylene total hip replacements with more than two years of follow-up, with no difference during the first two years after implantation. The results of the hazard ratios (and 95% confidence intervals) from the multivariable model at various durations of follow-up were 0.95 (0.74 to 1.23) at zero to two years (p = 0.698), 1.42 (1.16 to 1.75) at more than two years to four years (p = 0.001), 1.78 (1.45 to 2.19) at more than four years to six years (p < 0.001), and 2.15 (1.63 to 2.83) at more than six years to seven years (p < 0.001).

conclusionsWe conducted a comparison of large-head-size, metal-on-metal implants and metal-on-highly cross-linked polyethylene implants in younger patients with uncemented fixation. We found consistent and strong evidence worldwide that large-head-size, metal-on-metal implants were associated with increased risk of revision after two years compared with metal-on-highly cross-linked polyethylene implants, with the effect becoming more pronounced over time.

Indexed as

Hip ProsthesisProsthesis DesignArthroplasty, Replacement, HipFemaleHumansMaleMetalsMiddle AgedOsteoarthritis, HipPolyethylenesProsthesis FailureRegistriesTreatment OutcomeMetalsPolyethylenes

Identifiers

PMID25520416
PMCPMC4271426
OpenAlexW2152346350

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.