ArticleThe Journal of bone and joint surgery. American volume2014
Distributed analysis of hip implants using six national and regional registries: comparing metal-on-metal with metal-on-highly cross-linked polyethylene bearings in cementless total hip arthroplasty in young patients.
Article in The Journal of bone and joint surgery. American volume, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
26 citing papers in PubMed, 40 citations in OpenAlex.
- Revision rate of large head diameter metal-on-metal total hip arthroplasty: long-term results.Archives of orthopaedic and trauma surgery · 2026Article
- Long-term Performance and Durability of Biomaterials and Implant Designs in Total Joint Arthroplasty and Spinal Fusion.Journal of orthopaedics and sports medicine · 2026Article
- The Indian Joint Registry: Building Trust, Safety, and Excellence in Indian Orthopedics.Journal of orthopaedic case reports · 2025Article
- Isolated acetabular cup revision in Metal-on-Metal total hip arthroplasty: a low-complication strategy feasible in only half of cases.International orthopaedics · 2025Article
- 10-year follow-up results of the initial application of 3D-printed percutaneous guides in drilled decompression of femoral head necrosis.BMC musculoskeletal disorders · 2025Article
- The Long-Term Survivorship and Cause of Failure of Metal-on-Metal Total Hip Arthroplasty.Antibiotics (Basel, Switzerland) · 2025Article
- Periprosthetic Joint Infection After Total Knee Arthroplasty With or Without Antibiotic Bone Cement.JAMA network open · 2024Article
- Head, acetabular liner composition, and rate of revision and wear in total hip arthroplasty: a Bayesian network meta-analysis.Scientific reports · 2023Article
- Advancing the Real-World Evidence for Medical Devices through Coordinated Registry Networks.BMJ surgery, interventions, & health technologies · 2022Article
- No effect of delivery on total hip replacement survival: a nationwide register study in Finland.Acta orthopaedica · 2019Article
- Impact of hip arthroplasty registers on orthopaedic practice and perspectives for the future.EFORT open reviews · 2019Review
- Evaluation of the effectiveness of hip and knee implant models used in Catalonia: a protocol for a prospective registry-based study.Journal of orthopaedic surgery and research · 2019Observational
- Homogeneity in prediction of survival probabilities for subcategories of hipprosthesis data: the Nordic Arthroplasty Register Association, 2000-2013.Clinical epidemiology · 2019Article
- The experience of the RIPO, a shoulder prosthesis registry with 6-year follow-up.Musculoskeletal surgery · 2018Article
- Comparative Mid-term Follow-up Study of Primary Total Hip Arthroplasty with Metal-on-metal and Metal-on-polyethylene Bearings.Orthopaedic surgery · 2018Article
- Outcomes after revision of metal on metal hip resurfacing to total arthroplasty using the direct anterior approach.International orthopaedics · 2018Article
- What Is the Long-term Survival for Primary THA With Small-head Metal-on-metal Bearings?Clinical orthopaedics and related research · 2018Article
- Application of a Causal Discovery Algorithm to the Analysis of Arthroplasty Registry Data.Biomedical engineering and computational biology · 2018Review
- Midterm analysis of the seleXys cup with ceramic inlay.Arthroplasty today · 2017Article
- Complications Are Not Increased With Acetabular Revision of Metal-on-metal Total Hip Arthroplasty.Clinical orthopaedics and related research · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 7 institutions in 5 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe regulation of medical devices has attracted controversy recently because of problems related to metal-on-metal hip implants. There is growing evidence that metal-on-metal implants fail early and cause local and systemic complications. However, the failure associated with metal-on-metal head size is not consistently documented and needs to be communicated to patients and surgeons. The purpose of this study is to compare implant survival of metal on metal with that of metal on highly cross-linked polyethylene.
methodsUsing a distributed health data network, primary total hip arthroplasties were identified from six national and regional total joint arthroplasty registries (2001 to 2010). Inclusion criteria were patient age of forty-five to sixty-four years, cementless total hip arthroplasties, primary osteoarthritis diagnosis, and exclusion of the well-known outlier implant ASR (articular surface replacement). The primary outcome was revision for any reason. A meta-analysis of survival probabilities was performed with use of a fixed-effects model. Metal-on-metal implants with a large head size of >36 mm were compared with metal-on-highly cross-linked polyethylene implants.
resultsMetal-on-metal implants with a large head size of >36 mm were used in 5172 hips and metal-on-highly cross-linked polyethylene implants were used in 14,372 hips. Metal-on-metal total hip replacements with a large head size of >36 mm had an increased risk of revision compared with metal-on-highly cross-linked polyethylene total hip replacements with more than two years of follow-up, with no difference during the first two years after implantation. The results of the hazard ratios (and 95% confidence intervals) from the multivariable model at various durations of follow-up were 0.95 (0.74 to 1.23) at zero to two years (p = 0.698), 1.42 (1.16 to 1.75) at more than two years to four years (p = 0.001), 1.78 (1.45 to 2.19) at more than four years to six years (p < 0.001), and 2.15 (1.63 to 2.83) at more than six years to seven years (p < 0.001).
conclusionsWe conducted a comparison of large-head-size, metal-on-metal implants and metal-on-highly cross-linked polyethylene implants in younger patients with uncemented fixation. We found consistent and strong evidence worldwide that large-head-size, metal-on-metal implants were associated with increased risk of revision after two years compared with metal-on-highly cross-linked polyethylene implants, with the effect becoming more pronounced over time.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.