ArticlePloS one2014
Feasibility and reproducibility of echo planar spectroscopic imaging on the quantification of hepatic fat.
Article in PloS one, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Accelerated MR spectroscopic imaging-a review of current and emerging techniques.NMR in biomedicine · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectives1H-MRS is widely regarded as the most accurate noninvasive method to quantify hepatic fat content (HFC). When practical period of breath holding, and acquisition of HFC over multiple liver areas is considered, a fast MR spectroscopic imaging technique is desired. The aim of this study is to examine the feasibility and reproducibility of echo planar spectroscopic imaging (EPSI) on the quantification of HFC in subject with various HFCs.
methodsTwenty two volunteers were examined in a 3T MR system. The acquisition time of proposed EPSI protocol was 18 seconds. The EPSI scans were repeated 8 times for each subject to test reproducibility. The peak of water and individual peaks of fat including methyl, methylene, and allylic peaks at 0.9, 1.3, and 2.0 ppm were fitted. Calculated amount of water and fat content were corrected for T2 relaxation. The total HFC was defined as the combination of individual peaks. Standard deviation (SD), coefficient of variance (COV) and fitting reliability of HFC quantified by LCModel were calculated.
resultsOur results show that the SDs of total HFC for all subjects are less than 2.5%. Fitting reliability is mostly under 10% and positively correlates with COV. Subjects separated into three subgroups according to quantified total HFC show that improved fitting reliability and reproducibility can be achieved on subjects with higher total HFC.
conclusionsWe have demonstrated feasibility of the proposed EPSI protocols on the quantification of HFC over a whole slice of liver with scan time in a single breath hold.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.