Evidence map›Paper›PMID 25501096›Full record

SynthesisMedicine2014

CT-base pulmonary artery measurement in the detection of pulmonary hypertension: a meta-analysis and systematic review.

Yongchun Shen, Chun Wan, Panwen Tian, Yanqiu Wu, Xiaoou Li, Ting Yang, Jing An, Tao Wang, Lei Chen, Fuqiang Wen

Abstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in Medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 72 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
72citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

72 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Advances in the imaging of pulmonary hypertension.International journal of cardiology. Congenital heart disease · 2025
    Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article

12 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Yongchun ShenFrom the Department of Respiratory and Critical Care Medicine, West China Hospital of Sichuan University and Division of Pulmonary Diseases, State Key Laboratory of Biotherapy of China, Chengdu 610041, China.
Chun Wan
Panwen Tian
Yanqiu Wu
Xiaoou Li
Ting Yang
Jing An
Tao Wang
Lei Chen
Fuqiang Wen

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To summarize the performance of CT-based main pulmonary artery diameter or pulmonary artery to aorta ratio (PA:A ratio) measurement in detection of pulmonary hypertension by a systematic review and meta-analysis. A comprehensive literature search was performed to identify studies determining diagnostic accuracy of main pulmonary artery diameter or PA:A ratio measurement for pulmonary hypertension. The Quality Assessment of Diagnostic Accuracy Studies tool was used to assess the quality of the included studies. A bivariate random-effects model was used to pool sensitivity, specificity, positive/negative likelihood ratio (PLR/NLR), and diagnostic odds ratio (DOR). Summary receiver operating characteristic (SROC) curves and area under the curve (AUC) were used to summarize overall diagnostic performance. This meta-analysis included 20 publications involving 2134 subjects. Summary estimates for main pulmonary artery diameter measurement in the diagnosis of pulmonary hypertension were as follows: sensitivity, 0.79 (95% CI 0.72-0.84); specificity, 0.83 (95% CI 0.75-0.89); PLR, 4.68 (95% CI 3.13-6.99); NLR, 0.26 (95% CI 0.20-0.33); DOR, 18.13 (95% CI 10.87-30.24); and AUC 0.87. The corresponding summary performance estimates for using the PA:A ratio were as follows: sensitivity, 0.74 (95% CI 0.66-0.80); specificity, 0.81 (95% CI 0.74-0.86); PLR, 3.83 (95% CI, 2.70-5.43); NLR, 0.33 (95% CI 0.24-0.44); DOR, 11.77 (95% CI 6.60-21.00); and AUC 0.84. Both main pulmonary artery diameter and PA:A ratio are helpful for diagnosing pulmonary hypertension. Nevertheless, the results of pulmonary artery measurement should be interpreted in parallel with the results of traditional tests such as echocardiography.

Indexed as

AortographyHumansHypertension, PulmonaryPulmonary ArteryTomography, X-Ray Computed

Identifiers

PMID25501096
PMCPMC4602811

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.