Observational studyMedicine2014
Twenty-four-hour intraocular pressure related changes following adjuvant selective laser trabeculoplasty for normal tension glaucoma.
Observational study in Medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 1 synthesis or guideline pooled it, 36 citations in OpenAlex.
- Systematic Review of Current Devices for 24-h Intraocular Pressure Monitoring.Advances in therapy · 2016Pooled it
- 24-Hour efficacy of single primary selective laser trabeculoplasty versus latanoprost eye drops for Naïve primary open-angle glaucoma and ocular hypertension patients.Scientific reports · 2023Trial
- Trial
- Two-Year Outcome of Selective Laser Trabeculoplasty for Normal-Tension Glaucoma in Japan: First-Line or Second-Line Selective Laser Trabeculoplasty (FSS) Study.Journal of clinical medicine · 2025Article
- The relationship between intraocular pressure and glaucoma: An evolving concept.Progress in retinal and eye research · 2024Review
- Prediction of glaucoma progression by 24-h contact lens sensor profile in patients with normal-tension glaucoma.Scientific reports · 2024Article
- Efficacy and safety of first-line or second-line selective laser trabeculoplasty for normal-tension glaucoma: a multicentre cohort study.BMJ open ophthalmology · 2024Article
- Association of Ambulatory Blood Pressure and Other Factors With Intraocular Pressure-Related 24-Hour Contact Lens Sensor Profile in Untreated Glaucoma.Translational vision science & technology · 2022Article
- Selective laser trabeculoplasty: past, present, and future.Eye (London, England) · 2018Review
- The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives.Clinical ophthalmology (Auckland, N.Z.) · 2017Review
- The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns.Journal of ophthalmology · 2016Review
- The Effect of Laser Trabeculoplasty on Posture-Induced Intraocular Pressure Changes in Patients with Open Angle Glaucoma.PloS one · 2016Article
- Article
- Two-Year Clinical Results After Selective Laser Trabeculoplasty for Normal Tension Glaucoma.Medicine · 2015Article
- Noninvasive intraocular pressure monitoring: current insights.Clinical ophthalmology (Auckland, N.Z.) · 2015Review
- 24-hour Intraocular pressure monitoring: the way ahead.Romanian journal of ophthalmologyReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To investigate intraocular pressure (IOP) related patterns before and after selective laser trabeculoplasty (SLT) for normal tension glaucoma (NTG).In this prospective cohort study, 18 NTG patients underwent SLT. Success was defined as IOP reduction ≥ 20% by Goldmann applanation tonometry. 24-hour IOP-related pattern recording with a contact lens sensor (CLS) (SENSIMED Triggerfish, Sensimed, Switzerland) was done before (baseline) and 1 month after SLT. A cosine function was fitted to the mean CLS patterns for each individual in the SLT success and non-success groups and the amplitude before and after SLT was calculated. Diurnal, nocturnal, and 24-hour CLS pattern local variability was determined for pre- and post-SLT sessions. Cosine amplitude and variability were compared before and after SLT by group using paired t-tests, with α = 0.05. Patients (11 women, 7 men) had a mean age of 65.1 ± 13.7 years. Mean IOP was 15.3 ± 2.2 mm Hg at baseline and was reduced by 17.0% to 12.7 ± 1.8 mm Hg 1 month after SLT (P = 0.001). SLT was successful in 8 patients (44%). The amplitude of the fitted cosine was reduced by 24.6% in the success group, but displayed an amplitude increase of 19.2% post-SLT in the non-success group. Higher diurnal local variability of the CLS pattern was observed after SLT in non-success subjects (P = 0.002), while nocturnal variability showed no significant change. The increase in diurnal variability in the non-success group led to an increase in 24-hour variability in this group (P = 0.001). No change in local variability (diurnal, nocturnal, and 24-hour) was seen in the success group. The IOP-related pattern cosinor amplitude was reduced in NTG patients with a successful SLT treatment whereas the non-success group exhibited an increase of cosine amplitude. Higher diurnal and 24-hour CLS pattern variability was observed in non-success patients 1 month post-SLT.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.