ArticleProceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine2014
Computational investigation of the time-dependent contact behaviour of the human tibiofemoral joint under body weight.
Article in Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- A Musculoskeletal-Finite Element Study of Knee Joint Loading and Cartilage Mechanics in Children with Cerebral Palsy.Annals of biomedical engineering · 2026Article
- Biomechanical effects of medial osteoarthritis progression and UKA on knee lateral compartment using fibril-reinforced biphasic material in finite element study.Scientific reports · 2025Article
- A review of finite element modeling and surgical simulation of meniscal tear in knee joint: progress and challenges.Frontiers in medicine · 2025Review
- The effect of different posterior inclinations of tibial component on tibiofemoral contact pressures after unicompartmental knee arthroplasty.Journal of orthopaedic surgery and research · 2023Article
- High Tibial Osteotomy: Review of Techniques and Biomechanics.Journal of healthcare engineering · 2019Review
- Tissue material properties and computational modelling of the human tibiofemoral joint: a critical review.PeerJ · 2018Article
- The effects of geometric uncertainties on computational modelling of knee biomechanics.Royal Society open science · 2017Article
- Evaluating the effects of material properties of artificial meniscal implant in the human knee joint using finite element analysis.Scientific reports · 2017Article
- Relative contribution of articular cartilage's constitutive components to load support depending on strain rate.Biomechanics and modeling in mechanobiology · 2017Article
- Open Knee: Open Source Modeling and Simulation in Knee Biomechanics.The journal of knee surgery · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
The knee joint is one of the most common sites for osteoarthritis, the onset and progression of which are believed to relate to the mechanical environment of cartilage. To understand this environment, it is necessary to take into account the complex biphasic contact interactions of the cartilage and menisci. In this study, the time-dependent contact behaviour of an intact and a meniscectomized human tibiofemoral joint was characterized under body weight using a computational model. Good agreement in the contact area and femoral displacement under static loads were found between model predictions of this study and published experimental measurements. The time-dependent results indicated that as loading time progressed, the contact area and femoral vertical displacement of both intact and meniscectomized joints increased. More load was transferred to the cartilage-cartilage interface over time. However, the portions of load borne by the lateral and medial compartments did not greatly vary with time. Additionally, during the whole simulation period, the maximum compressive stress in the meniscectomized joint was higher than that in the intact joint. The fluid pressure in the intact and meniscectomized joints remained remarkably high at the condyle centres, but the fluid pressure at the cartilage-meniscus interface decreased faster than that at the condyle centres as loading time progressed. The above findings provide further insights into the mechanical environment of the cartilage and meniscus within the human knee joint.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.