Evidence map›Paper›PMID 25495771›Full record

ArticleBMC pulmonary medicine2014

Pulsed direct and constant direct currents in the pilocarpine iontophoresis sweat chloride test.

Carla Cristina Souza Gomez, Maria de Fatima Servidoni, Fernando Augusto de Lima Marson, Paulo Jose Coelho Canavezi, Adriana Mendes Vinagre, Eduardo Tavares Costa, Antonio Fernando Ribeiro, Maria Angela Gonçalves de Oliveira Ribeiro, Adyleia Aparecida Dalbo Contrera Toro, Celia Regina Pavan and 4 more

Open access · goldAbstract readComparative Study
In one paragraph

Article in BMC pulmonary medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors at 1 institution in 1 country.

Carla Cristina Souza GomezDepartament of Pediatrics, Faculty of Medical Sciences, State University of Campinas, 13083-887 Campinas, SP, Brazil. carlacg.gomez@gmail.com.
Maria de Fatima Servidoni
Fernando Augusto de Lima Marson
Paulo Jose Coelho Canavezi
Adriana Mendes Vinagre
Eduardo Tavares Costa
Antonio Fernando Ribeiro
Maria Angela Gonçalves de Oliveira Ribeiro
Adyleia Aparecida Dalbo Contrera Toro
Celia Regina Pavan
Michelle Vivine Sá Dos Santos Rondon
Sonia Leticia Silva Lorena
Francisco Ubaldi Vieria
Jose Dirceu Ribeiro
Universidade Estadual de Campinas (UNICAMP) · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe classic sweat test (CST) is the golden standard for cystic fibrosis (CF) diagnosis. Then, our aim was compare the production and volume of sweat, and side effects caused by pulsed direct current (PDC) and constant direct current (CDC). To determine the optimal stimulation time (ST) for the sweat collection. To verify the PDC as CF diagnosis option.

methodsProspective study with cross-sectional experimental intervention. Experiment 1 (right arm): PDC and CDC. ST at 10 min and sweat collected at 30 min. Currents of 0.5; 0.75; 1.0 and 1.5 mA and frequencies of 0, 200, 1,000 and 5,000 Hz applied. Experiment 2 (left arm): current of 1.0 mA, ST at 5 and 10 min and sweat collected at 15 and 30 min with frequencies of 0; 200; 1,000 and 5,000 Hz applied Experiments 1 and 2 were performed with current density (CD) from 0.07 to 0.21 mA/cm2. Experiment 3: PDC was used in typical CF patients with two CFTR mutations screened and or with CF diagnosis by rectal biopsy and patients with atypical CF.

results48 subjects (79.16% female) with average of 29.54 ± 8.87 years old were enrolled. There was no statistical difference between the interaction of frequency and current in the sweat weight (p = 0.7488). Individually, positive association was achieved between weight sweat and stimulation frequency (p = 0.0088); and current (p = 0.0025). The sweat production was higher for 10 min of stimulation (p = 0.0023). The sweat collection was better for 30 min (p = 0.0019). The skin impedance was not influenced by ST and sweat collection (p > 0.05). The current frequency was inversely associated with the skin impedance (p < 0.0001). The skin temperature measured before stimulation was higher than after (p < 0.0001). In Experiment 3 (29 subjects) the PDC showed better kappa index compared to CDC (0.9218 versus 0.5205, respectively).

conclusionsThe performance of the CST with CDC and PDC with CD of 0.14 to 0.21 mA/cm2 showed efficacy in steps of stimulation and collection of sweat, without side effects. The optimal stimulation time and sweat collection were, respectively, 10 and 30 min.

Indexed as

AdultBiopsyChloridesCystic FibrosisElectric ImpedanceElectrodiagnosisFemaleHumansIontophoresisMaleMuscarinic AgonistsPilocarpineProspective StudiesRectumSweatSweat GlandsChloridesMuscarinic AgonistsPilocarpine

Identifiers

PMID25495771
PMCPMC4290820
OpenAlexW2016784709

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.