Evidence map›Paper›PMID 25471983›Full record

ArticleMedical physics2014

Microwave ablation energy delivery: influence of power pulsing on ablation results in an ex vivo and in vivo liver model.

Mariajose Bedoya, Alejandro Muñoz del Rio, Jason Chiang, Christopher L Brace

Abstract read
In one paragraph

Article in Medical physics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Effects of Pulsed Radiofrequency Source on Cardiac Ablation.Bioengineering (Basel, Switzerland) · 2023
    Article
  7. Creation of an Ex Vivo Renal Perfusion Model to Investigate Microwave Ablation.Journal of vascular and interventional radiology : JVIR · 2023
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. How large is the periablational zone after radiofrequency and microwave ablation? Computer-based comparative study of two currently used clinical devices.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2020
    Article
  13. Article
  14. Article
  15. Microwave ablation in primary and secondary liver tumours: technical and clinical approaches.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2017
    Review
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mariajose BedoyaDepartment of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 and Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin 53705.
Alejandro Muñoz del RioDepartment of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 and Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin 53705.
Jason ChiangDepartment of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53705 and Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin 53705.
Christopher L BraceDepartment of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705; Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53705; and Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin 53705.

Funding

Structure and function of chloride channels and transportersR01GM085232 · NIGMS · WEILL MEDICAL COLL OF CORNELL UNIV · PI ACCARDI, ALESSIO · 2009 to 2013
$1.7M
NCI NIH HHS 1R01CA14273701NIGMS NIH HHS R01 GM085232NIGMS NIH HHS R25GM085232
6 · The paper itself

Abstract

purposeThe purpose of this study was to compare the impact of continuous and pulsed energy deliveries on microwave ablation growth and shape in unperfused and perfused liver models.

methodsA total of 15 kJ at 2.45 GHz was applied to ex vivo bovine liver using one of five delivery methods (n = 50 total, 10 per group): 25 W continuous for 10 min (25 W average), 50 W continuous for 5 min (50 W average), 100 W continuous for 2.5 min (100 W average), 100 W pulsed for 10 min (25 W average), and 100 W pulsed for 5 min (50 W average). A total of 30 kJ was applied to in vivo porcine livers (n = 35, 7 per group) using delivery methods similar to the ex vivo study, but with twice the total ablation time to offset heat loss to blood perfusion. Temperatures were monitored 5-20 mm from the ablation antenna, with values over 60 °C indicating acute cellular necrosis. Comparisons of ablation size and shape were made between experimental groups based on total energy delivery, average power applied, and peak power using ANOVA with post-hoc pairwise tests.

resultsNo significant differences were noted in ablation sizes or circularities between pulsed and continuous groups in ex vivo tissue. Temperature data demonstrated more rapid heating in pulsed ablations, suggesting that pulsing may overcome blood perfusion and coagulate tissues more rapidly in vivo. Differences in ablation size and shape were noted in vivo despite equivalent energy delivery among all groups. Overall, the largest ablation volume in vivo was produced with 100 W continuous for 5 min (265.7 ± 208.1 cm(3)). At 25 W average, pulsed-power ablation volumes were larger than continuous-power ablations (67.4 ± 34.5 cm(3) versus 23.6 ± 26.5 cm(3), P = 0.43). Similarly, pulsed ablations produced significantly greater length (P ≤ 0.01), with increase in diameter (P = 0.09) and a slight decrease in circularity (P = 0.97). When comparing 50 W average power groups, moderate differences in size were noted (P ≥ 0.06) and pulsed ablations were again slightly more circular.

conclusionsPulsed energy delivery created larger ablation zones at low average power compared to continuous energy delivery in the presence of blood perfusion. Shorter duty cycles appear to provide greater benefit when pulsing.

Indexed as

AnimalsBiophysical PhenomenaCattleFemaleHyperthermia, InducedIn Vitro TechniquesLiverLiver NeoplasmsMicrowavesModels, AnimalSus scrofa

Identifiers

PMID25471983
PMCPMC4240778

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.