Evidence map›Paper›PMID 25462956›Full record

ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2014

Digitally generated excitation and near-baseband quadrature detection of rapid scan EPR signals.

Mark Tseitlin, Zhelin Yu, Richard W Quine, George A Rinard, Sandra S Eaton, Gareth R Eaton

Abstract read
In one paragraph

Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. EPR Everywhere.Applied magnetic resonance · 2021
    Review
  2. Modular imaging system: Rapid scan EPR at 800 MHz.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2019
    Article
  3. Development of an L-band rapid scan EPR digital console.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2019
    Article
  4. Background correction in rapid scan EPR spectroscopy.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2018
    Article
  5. Full cycle rapid scan EPR deconvolution algorithm.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017
    Article
  6. Rapid-scan EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017
    Review
  7. Field-stepped direct detection electron paramagnetic resonance.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2015
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mark TseitlinDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80210, USA.
Zhelin YuDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80210, USA.
Richard W QuineSchool of Engineering and Computer Science, University of Denver, Denver, CO 80210, USA.
George A RinardSchool of Engineering and Computer Science, University of Denver, Denver, CO 80210, USA.
Sandra S EatonDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80210, USA.
Gareth R EatonDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80210, USA. Electronic address: geaton@du.edu.

Funding

Rapid Scan Biomedical EPR Spectroscopy and ImagingR01EB000557 · NIBIB · UNIVERSITY OF DENVER (COLORADO SEMINARY) · PI EATON, GARETH R · 2002 to 2011
$4.0M
Rapid Scan Biomedical EPR Spectroscopy and ImagingR56EB000557 · NIBIB · UNIVERSITY OF DENVER (COLORADO SEMINARY) · PI EATON, GARETH R · 2007 to 2007
$494k
Enhancing in vivo EPR imaging using spin probes with short relaxation timesK25EB016040 · NIBIB · WEST VIRGINIA UNIVERSITY · PI TSEYTLIN, MARK · 2013 to 2015
$416k
NIBIB NIH HHS K25 EB016040NIBIB NIH HHS R01 EB000557NIBIB NIH HHS R56 EB000557
6 · The paper itself

Abstract

The use of multiple synchronized outputs from an arbitrary waveform generator (AWG) provides the opportunity to perform EPR experiments differently than by conventional EPR. We report a method for reconstructing the quadrature EPR spectrum from periodic signals that are generated with sinusoidal magnetic field modulation such as continuous wave (CW), multiharmonic, or rapid scan experiments. The signal is down-converted to an intermediate frequency (IF) that is less than the field scan or field modulation frequency and then digitized in a single channel. This method permits use of a high-pass analog filter before digitization to remove the strong non-EPR signal at the IF, that might otherwise overwhelm the digitizer. The IF is the difference between two synchronized X-band outputs from a Tektronix AWG 70002A, one of which is for excitation and the other is the reference for down-conversion. To permit signal averaging, timing was selected to give an exact integer number of full cycles for each frequency. In the experiments reported here the IF was 5kHz and the scan frequency was 40kHz. To produce sinusoidal rapid scans with a scan frequency eight times IF, a third synchronized output generated a square wave that was converted to a sine wave. The timing of the data acquisition with a Bruker SpecJet II was synchronized by an external clock signal from the AWG. The baseband quadrature signal in the frequency domain was reconstructed. This approach has the advantages that (i) the non-EPR response at the carrier frequency is eliminated, (ii) both real and imaginary EPR signals are reconstructed from a single physical channel to produce an ideal quadrature signal, and (iii) signal bandwidth does not increase relative to baseband detection. Spectra were obtained by deconvolution of the reconstructed signals for solid BDPA (1,3-bisdiphenylene-2-phenylallyl) in air, 0.2mM trityl OX63 in water,

Indexed as

Arbitrary wave form generatorDigital EPRRapid scan EPR

Identifiers

PMID25462956
PMCPMC4416072

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.