Evidence map›Paper›PMID 25462795›Full record

ArticleNeuroImage2015

Dynamic multi-coil technique (DYNAMITE) shimming for echo-planar imaging of the human brain at 7 Tesla.

Christoph Juchem, S Umesh Rudrapatna, Terence W Nixon, Robin A de Graaf

Open access · greenAbstract read
In one paragraph

Article in NeuroImage, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers.

0numbers the graph read from it
0cells of the map it votes in
34citing papers in PubMed
4.8field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

34 citing papers in PubMed, 75 citations in OpenAlex.

  1. Correcting motion-related BScientific reports · 2026
    Article
  2. Article
  3. Accelerated Navigator for Rapid ∆BNMR in biomedicine · 2025
    Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Review
  9. 3D FRONSAC with PSF reconstruction.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2023
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. A 31-channel integrated "AC/DC" BMagnetic resonance in medicine · 2022
    Article
  16. Article
  17. Article
  18. Article
  19. An orthogonal shim coil for 3T brain imaging.Magnetic resonance in medicine · 2020
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Christoph JuchemYale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), 300 Cedar Street, New Haven, CT 06520, USA. Electronic address: christoph.juchem@yale.edu.
S Umesh RudrapatnaYale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), 300 Cedar Street, New Haven, CT 06520, USA.
Terence W NixonYale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), 300 Cedar Street, New Haven, CT 06520, USA.
Robin A de GraafYale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), 300 Cedar Street, New Haven, CT 06520, USA.
Yale University · US

Funding

Bioimaging and Intervention in Neocortical EpilepsyR01EB000473 · NIBIB · YALE UNIVERSITY · PI DUNCAN, JAMES S · 2002 to 2011
$13.3M
NeurophysiologicP30NS052519 · NINDS · YALE UNIVERSITY · PI HYDER, DEWAN SYED FAHMEED · 2007 to 2017
$6.7M
Robust 3D MR spectroscopic imaging through multi-coil magnetic field shapingR01EB014861 · NIBIB · YALE UNIVERSITY · PI DE GRAAF, ROBIN A · 2012 to 2020
$3.3M
NIBIB NIH HHS R01 EB000473NIBIB NIH HHS R01-EB000473NIBIB NIH HHS R01 EB014861NIBIB NIH HHS R01-EB014861NINDS NIH HHS P30 NS052519NINDS NIH HHS P30-NS052519
6 · The paper itself

Abstract

Gradient-echo echo-planar imaging (EPI) is the primary method of choice in functional MRI and other methods relying on fast MRI to image brain activation and connectivity. However, the high susceptibility of EPI towards B0 magnetic field inhomogeneity poses serious challenges. Conventional magnetic field shimming with low-order spherical harmonic (SH) functions is capable of compensating shallow field distortions, but performs poorly for global brain shimming or on specific areas with strong susceptibility-induced B0 distortions such as the prefrontal cortex (PFC). Excellent B0 homogeneity has been demonstrated recently in the human brain at 7 Tesla with the DYNAmic Multi-coIl TEchnique (DYNAMITE) for magnetic field shimming (J Magn Reson (2011) 212:280-288). Here, we report the benefits of DYNAMITE shimming for multi-slice EPI and T2* mapping. A standard deviation of 13Hz was achieved for the residual B0 distribution in the human brain at 7 Tesla with DYNAMITE shimming and was 60% lower compared to conventional shimming that employs static zero through third order SH shapes. The residual field inhomogeneity with SH shimming led to an average 8mm shift at acquisition parameters commonly used for fMRI and was reduced to 1.5-3mm with DYNAMITE shimming. T2* values obtained from the prefrontal and temporal cortices with DYNAMITE shimming were 10-50% longer than those measured with SH shimming. The reduction of the confounding macroscopic B0 field gradients with DYNAMITE shimming thereby promises improved access to the relevant microscopic T2* effects. The combination of high spatial resolution and DYNAMITE shimming allows largely artifact-free EPI and T2* mapping throughout the brain, including prefrontal and temporal lobe areas. DYNAMITE shimming is expected to critically benefit a wide range of MRI applications that rely on excellent B0 magnetic field conditions including EPI-based fMRI to study various cognitive processes and assessing large-scale brain connectivity in vivo. As such, DYNAMITE shimming has the potential to replace conventional SH shim systems in human MR scanners.

Indexed as

AdultBrainEcho-Planar ImagingFemaleHumansImage Processing, Computer-AssistedMaleMiddle AgedDynamic shimmingEcho planar imaging (EPI)EPI artifactsMulti-coilShimmingSpherical harmonics

Identifiers

PMID25462795
PMCPMC4262558
OpenAlexW2050097404

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.