ArticleNeuroImage2015
Dynamic multi-coil technique (DYNAMITE) shimming for echo-planar imaging of the human brain at 7 Tesla.
Article in NeuroImage, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
34 citing papers in PubMed, 75 citations in OpenAlex.
- Correcting motion-related BScientific reports · 2026Article
- Improving magnetic field homogeneity in prostate MR imaging and spectroscopy using an add-on local external shim coil array.Magma (New York, N.Y.) · 2026Article
- Accelerated Navigator for Rapid ∆BNMR in biomedicine · 2025Article
- Localized Shims Enable Low-Field Simultaneous Multinuclear NMR Spectroscopy.Analytical chemistry · 2024Article
- High-quality lipid suppression and B0 shimming for human brainNeuroImage · 2024Article
- Artificial intelligence for neuro MRI acquisition: a review.Magma (New York, N.Y.) · 2024Review
- Article
- Advancements in MR hardware systems and magnetic field control: BPsychoradiology · 2024Review
- 3D FRONSAC with PSF reconstruction.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2023Article
- Naturalistic Hyperscanning with Wearable Magnetoencephalography.Sensors (Basel, Switzerland) · 2023Article
- Hybrid active and passive local shimming (HAPLS) for two-region MRI.Magnetic resonance in medicine · 2023Article
- Physical limits to human brain B0 shimming with spherical harmonics, engineering implications thereof.Magma (New York, N.Y.) · 2022Article
- Multiple sclerosis diagnosis and phenotype identification by multivariate classification of in vivo frontal cortex metabolite profiles.Scientific reports · 2022Article
- A lightweight magnetically shielded room with active shielding.Scientific reports · 2022Article
- A 31-channel integrated "AC/DC" BMagnetic resonance in medicine · 2022Article
- Application of an integrated radio-frequency/shim coil technology for signal recovery in fMRI.Magnetic resonance in medicine · 2021Article
- High-resolution fMRI at 7 Tesla: challenges, promises and recent developments for individual-focused fMRI studies.Current opinion in behavioral sciences · 2021Article
- Dynamic multicoil technique (DYNAMITE) MRI on human brain.Magnetic resonance in medicine · 2020Article
- An orthogonal shim coil for 3T brain imaging.Magnetic resonance in medicine · 2020Article
- High-fidelity, high-isotropic-resolution diffusion imaging through gSlider acquisition withMagnetic resonance in medicine · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
Gradient-echo echo-planar imaging (EPI) is the primary method of choice in functional MRI and other methods relying on fast MRI to image brain activation and connectivity. However, the high susceptibility of EPI towards B0 magnetic field inhomogeneity poses serious challenges. Conventional magnetic field shimming with low-order spherical harmonic (SH) functions is capable of compensating shallow field distortions, but performs poorly for global brain shimming or on specific areas with strong susceptibility-induced B0 distortions such as the prefrontal cortex (PFC). Excellent B0 homogeneity has been demonstrated recently in the human brain at 7 Tesla with the DYNAmic Multi-coIl TEchnique (DYNAMITE) for magnetic field shimming (J Magn Reson (2011) 212:280-288). Here, we report the benefits of DYNAMITE shimming for multi-slice EPI and T2* mapping. A standard deviation of 13Hz was achieved for the residual B0 distribution in the human brain at 7 Tesla with DYNAMITE shimming and was 60% lower compared to conventional shimming that employs static zero through third order SH shapes. The residual field inhomogeneity with SH shimming led to an average 8mm shift at acquisition parameters commonly used for fMRI and was reduced to 1.5-3mm with DYNAMITE shimming. T2* values obtained from the prefrontal and temporal cortices with DYNAMITE shimming were 10-50% longer than those measured with SH shimming. The reduction of the confounding macroscopic B0 field gradients with DYNAMITE shimming thereby promises improved access to the relevant microscopic T2* effects. The combination of high spatial resolution and DYNAMITE shimming allows largely artifact-free EPI and T2* mapping throughout the brain, including prefrontal and temporal lobe areas. DYNAMITE shimming is expected to critically benefit a wide range of MRI applications that rely on excellent B0 magnetic field conditions including EPI-based fMRI to study various cognitive processes and assessing large-scale brain connectivity in vivo. As such, DYNAMITE shimming has the potential to replace conventional SH shim systems in human MR scanners.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.