Evidence map›Paper›PMID 25436207›Full record

ArticleHeart, lung and vessels2014

Effects of transcatheter aortic valve implantation on left ventricular mass and global longitudinal strain: tissue Doppler and strain evaluation.

E Vizzardi, E Sciatti, I Bonadei, R Rovetta, A D'Aloia, S Gelsomino, R Lorusso, F Ettori, M Metra

Open access · greenAbstract read
In one paragraph

Article in Heart, lung and vessels, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Role of myocardial strain and rotation for predicting prosthetic aortic valve stenosis.The international journal of cardiovascular imaging · 2022
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

E VizzardiSection of Cardiovascular Diseases, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Study of Brescia, Italy.
E SciattiSection of Cardiovascular Diseases, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Study of Brescia, Italy.
I BonadeiSection of Cardiovascular Diseases, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Study of Brescia, Italy.
R RovettaSection of Cardiovascular Diseases, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Study of Brescia, Italy.
A D'AloiaSection of Cardiovascular Diseases, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Study of Brescia, Italy.
S GelsominoCardiovascular Research Institute Maastricht - CARIM, Maastricht University Medical Centre, The Netherlands.
R LorussoCardiac Surgery Unit, Spedali Civili of Brescia, Italy.
F EttoriSection of Cardiovascular Diseases, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Study of Brescia, Italy.
M MetraSection of Cardiovascular Diseases, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Study of Brescia, Italy.
University of Brescia · ITAzienda Socio Sanitaria Territoriale degli Spedali Civili di Brescia · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionTranscatheter aortic valve implantation is the option of choice for high surgical risk patients suffering from symptomatic aortic stenosis. We aimed to evaluate the influence of baseline global longitudinal strain on left ventricular mass regression after the procedure.

methodsWe enrolled 23 patients with pure symptomatic severe aortic stenosis who underwent CoreValve prosthesis (Medtronic, Minneapolis, MN) implantation. Everyone had echocardiography registration before the procedure and after six months in order to analyze two-, three-, and four-chamber peak longitudinal strain and global longitudinal strain.

resultsAfter the procedure New York Heart Association class, peak and mean aortic valve gradients (p<0.001 for all) improved. Interventricular septum and posterior wall thicknesses decreased (p<0.001 for both). Moreover, left ventricular mass index for body surface area changed from 190±44 to 143±30 g/m(2), (p<0.001). Finally, global longitudinal strain significantly increased (from 9.4±0.9 to 11.5±0.8%; p<0.001), as well as its components. Baseline global longitudinal strain correlated with left ventricular mass regression (r=0.560; p=0.005; 2-sided) and predicted it at linear regression analysis (B=23.707; p=0.005; adjusted R(2)=0.281).

conclusionsGlobal longitudinal strain and its components improved six months after the procedure. Moreover, baseline global longitudinal strain seemed to predict left ventricular mass regression in patients with pure aortic stenosis undergoing transcatheter aortic valve implantation. This finding could be related to the extent of myocardial fibrosis which is also responsible for lack of left ventricular mass regression and poorer prognosis.

Indexed as

aortic valveechocardiographytranscatheter valve implantation

Identifiers

PMID25436207
PMCPMC4246844
OpenAlexW2139918165

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390