Evidence map›Paper›PMID 25428608›Full record

ArticleBMC ophthalmology2014

The effect of incorrect scanning distance on boundary detection errors and macular thickness measurements by spectral domain optical coherence tomography: a cross sectional study.

Boglárka Enikő Varga, Erika Tátrai, Delia Cabrera DeBuc, Gábor Márk Somfai

Abstract read
In one paragraph

Article in BMC ophthalmology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Boglárka Enikő Varga
Erika Tátrai
Delia Cabrera DeBuc
Gábor Márk SomfaiDepartment of Ophthalmology, Faculty of Medicine, Semmelweis University, 39 Mária Str,, Budapest 1085, Hungary. somfaigm@yahoo.com.

Funding

Advanced imaging for diabetic retinopathyR01EY020607 · NEI · UNIVERSITY OF MIAMI SCHOOL OF MEDICINE · PI CABRERA-DEBUC, DELIA · 2011 to 2015
$2.0M
NEI NIH HHS R01 EY020607
6 · The paper itself

Abstract

backgroundTo investigate the influence of scan distance on retinal boundary detection errors (RBDEs) and retinal thickness measurements by spectral domain optical coherence tomography (SD-OCT).

methods10 eyes of healthy subjects, 10 eyes with diabetic macular edema (DME) and 10 eyes with neovascular age-related macular degeneration (AMD) were examined with RTVue SD-OCT. The MM5 protocol was used in two consecutive sessions to scan the macula. For the first session, the device was set 3.5 cm from the eye in order to obtain detectable signal with low fundus image quality (suboptimal setting) while in the second session a distance of 2.5 cm was set with a good quality fundus image. The signal strength (SSI) value was recorded. The score for retinal boundary detection errors (RBDE) was calculated for ten scans of each examination. RBDE scores were recorded for the whole scan and also for the peripheral 1.0 mm region. RBDE scores, regional retinal thickness values and SSI values between the two sessions were compared. The correlation between SSI and the number of RBDEs was also examined.

resultsThe SSI was significantly lower with suboptimal settings compared to optimal settings (63.9±12.0 vs. 68.3±12.2, respectively, p = 0.001) and the number of RBDEs was significantly higher with suboptimal settings in the "all-eyes" group along with the group of healthy subjects and eyes with DME (9.1±6.5 vs. 6.8±6.3, p = 0.007; 4.4±2.6 vs. 2.5±1.6, p = 0.035 and 9.7±3.3 vs. 5.1±3.7, p = 0.008, respectively). For these groups, significant negative correlation was found between the SSI and the number of RBDEs. In the AMD group, the number of RBDEs was markedly higher compared to the other groups and there was no difference in RBDEs between optimal and suboptimal settings with the errors being independent of the SSI. There were significantly less peripheral RBDEs with optimal settings in the "all-eyes" group and the DME subgroup (2.7±2.6 vs. 4.2±2.8, p = 0.001 and 1.4±1.7 vs. 4.1±2.2, p = 0.007, respectively). Retinal thickness in the two settings was significantly different only in the outer-superior region in DME.

conclusionsOptimal distance settings improve SD-OCT SSI with a decrease in RBDEs while retinal thickness measurements are independent of scanning distance.

Indexed as

Diagnostic ErrorsCross-Sectional StudiesDiabetic RetinopathyHealthy VolunteersHumansMacular EdemaOrgan SizeProspective StudiesRetinaTomography, Optical CoherenceWet Macular Degeneration

Identifiers

PMID25428608
PMCPMC4280767

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.