Evidence map›Paper›PMID 25423875›Full record

Trial reportKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2016

Superior alignment but no difference in clinical outcome after minimally invasive computer-assisted unicompartmental knee arthroplasty (MICA-UKA).

Zhenxiang Zhang, Wei Zhu, Lixian Zhu, Yaqing Du

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. [Research development of computer assisted navigation and robotics in unicompartmental knee arthroplasty].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2017
    Review
  9. Article
  10. Article
  11. Review
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Zhenxiang ZhangOrthopedic Department, The Affiliated Taizhou People's Hospital of Nantong University, Yingchun Road, Taizhou, 225300, Jiangsu, China.
Wei ZhuOrthopedic Department, The Affiliated Taizhou People's Hospital of Nantong University, Yingchun Road, Taizhou, 225300, Jiangsu, China. kafeimao1982@126.com.
Lixian ZhuOrthopedic Department, The Affiliated Taizhou People's Hospital of Nantong University, Yingchun Road, Taizhou, 225300, Jiangsu, China.
Yaqing DuOrthopedic Department, The Affiliated Taizhou People's Hospital of Nantong University, Yingchun Road, Taizhou, 225300, Jiangsu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeVariety of clinical trials have been published comparing the alignment of MICA-UKA with MI-UKA. However, to the best of our knowledge, no published study has showed whether radiological alignment by MICA-UKA has influence on the clinical results. The present study was conducted to compare the short-term results of MICA-UKA with MI-UKA. It was hypothesized that better alignment as well as clinical results was achieved by MICA-UKA as compared to MI-UKA.

methodsThe clinical and radiological results of 87 subjects who underwent primary UKA using either minimally invasive and computer-assisted technique (45 patients Group A) or minimally invasive technique (42 patients, Group B) were reported. Knee Society scores (KSSs), Knee Society functional scores (KSFSs), range of motion (ROM), and radiographic results were assessed and reported preoperatively and at 24-month follow-up. Total blood loss, operative time, and length of skin incision were compared.

resultsThe accuracy of the implantations in relation to the coronal mechanical axis in Group A was significantly superior to that of Group B (P = 0.033). The femoral rotational profile revealed the prosthesis in Group A that was implanted with significantly less internal rotation than Group B (P = 0.025). Clinical results, with regard to ROMs and KSSs, as well as KSFSs were equally good in both the groups. The average blood loss in patients of Group A was significantly reduced as compared to patients of Group B. No significant difference was detected in terms of operative time or length of skin incision.

conclusionsIt is suggested that MICA-UKA improves the implant alignment without increasing clinical results versus MI-UKA. We advocate that computer navigation should be considered when minimally invasive unicompartmental knee arthroplasty is performed. LEVEL OF EVIDENCE: Therapeutic study, Level II.

Indexed as

Outcome Assessment, Health CareAgedArthroplasty, Replacement, KneeBone MalalignmentFemaleFollow-Up StudiesHumansKnee JointMaleMiddle AgedOsteoarthritis, KneeRange of Motion, ArticularSurgery, Computer-AssistedClinical outcomeComputer assistedMinimally invasive surgeryShort-term resultsUnicompartmental knee arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.