Evidence map›Paper›PMID 25421603›Full record

ArticleMagnetic resonance in medicine2015

A novel coil array for combined TMS/fMRI experiments at 3 T.

Lucia I Navarro de Lara, Christian Windischberger, Andre Kuehne, Michael Woletz, Jürgen Sieg, Sven Bestmann, Nikolaus Weiskopf, Bernhard Strasser, Ewald Moser, Elmar Laistler

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Safety and recommendations for TMS use in healthy subjects and patient populations, with updates on training, ethical and regulatory issues: Expert Guidelines.Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2021
    Guideline
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Review
  16. Review
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Lucia I Navarro de LaraCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Christian WindischbergerCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Andre KuehneCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Michael WoletzCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Jürgen SiegCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Sven BestmannSobell Department of Motor Neuroscience and Movement Disorders, UCL Institute of Neurology, University College London, London, United Kingdom.
Nikolaus WeiskopfWellcome Trust Centre for Neuroimaging, University College London, London, United Kingdom.
Bernhard StrasserMR Centre of Excellence, Medical University of Vienna, Vienna, Austria.
Ewald MoserCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Elmar LaistlerCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.

Funding

Wellcome Trust 091593
6 · The paper itself

Abstract

purposeTo overcome current limitations in combined transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) studies by employing a dedicated coil array design for 3 Tesla.

methodsThe state-of-the-art setup for concurrent TMS/fMRI is to use a large birdcage head coil, with the TMS between the subject's head and the MR coil. This setup has drawbacks in sensitivity, positioning, and available imaging techniques. In this study, an ultraslim 7-channel receive-only coil array for 3 T, which can be placed between the subject's head and the TMS, is presented. Interactions between the devices are investigated and the performance of the new setup is evaluated in comparison to the state-of-the-art setup.

resultsMR sensitivity obtained at the depth of the TMS stimulation is increased by a factor of five. Parallel imaging with an acceleration factor of two is feasible with low g-factors. Possible interactions between TMS and the novel hardware were investigated and were found negligible.

conclusionThe novel coil array is safe, strongly improves signal-to-noise ratio in concurrent TMS/fMRI experiments, enables parallel imaging, and allows for flexible positioning of the TMS on the head while ensuring efficient TMS stimulation due to its ultraslim design.

Indexed as

AdultComputer SimulationEquipment DesignFemaleHeadHumansMagnetic Resonance ImagingMalePhantoms, ImagingTranscranial Magnetic Stimulationcoil arrayconcurrent TMS/fMRIfMRIparallel imagingTMS

Identifiers

PMID25421603
PMCPMC4737243

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked