ArticleBiophysical journal2014
Penetration of cell membranes and synthetic lipid bilayers by nanoprobes.
Article in Biophysical journal, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed.
- Exploring Biophysics at the Membrane with Single-Molecule TIRF Microscopy.Advances in experimental medicine and biology · 2026Review
- Assessing the Feasibility of DevelopingFrontiers in neuroscience · 2021Article
- Ultrastructural Analysis of Neuroimplant-Parenchyma Interfaces Uncover Remarkable Neuroregeneration Along-With Barriers That Limit the Implant Electrophysiological Functions.Frontiers in neuroscience · 2021Article
- Nanoneedle-Based Materials for Intracellular Studies.Advances in experimental medicine and biology · 2021Article
- Design and Assessment of a Polyurethane Carrier Used for the Transmembrane Transfer of Acyclovir.Nanomaterials (Basel, Switzerland) · 2020Article
- Photocatalytic Nanofabrication and Intracellular Raman Imaging of Living Cells with Functionalized AFM Probes.Micromachines · 2020Article
- Bioelectronics for Millimeter-Sized Model Organisms.iScience · 2020Review
- High-Aspect-Ratio Nanostructured Surfaces as Biological Metamaterials.Advanced materials (Deerfield Beach, Fla.) · 2020Review
- Engineering microscale systems for fully autonomous intracellular neural interfaces.Microsystems & nanoengineering · 2020Article
- Low-Impedance 3D PEDOT:PSS Ultramicroelectrodes.Frontiers in neuroscience · 2020Article
- Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts.Chemical reviews · 2018Review
- Architecture of a mammalian glomerular domain revealed by novel volume electroporation using nanoengineered microelectrodes.Nature communications · 2018Article
- Multisite Attenuated Intracellular Recordings by Extracellular Multielectrode Arrays, a Perspective.Frontiers in neuroscience · 2018Article
- Multisite electrophysiological recordings by self-assembled loose-patch-like junctions between cultured hippocampal neurons and mushroom-shaped microelectrodes.Scientific reports · 2016Article
- Oscillating high-aspect-ratio monolithic silicon nanoneedle array enables efficient delivery of functional bio-macromolecules into living cells.Scientific reports · 2015Article
- Mapping Local Cytosolic Enzymatic Activity in Human Esophageal Mucosa with Porous Silicon Nanoneedles.Advanced materials (Deerfield Beach, Fla.) · 2015Article
- A feasibility study of multi-site,intracellular recordings from mammalian neurons by extracellular gold mushroom-shaped microelectrodes.Scientific reports · 2015Article
Corrections and comments
- Erratum issuedCorrection.2014
- Erratum issued
Authors and funding
5 authors.
Funding
Abstract
Nanoscale devices have been proposed as tools for measuring and controlling intracellular activity by providing electrical and/or chemical access to the cytosol. Unfortunately, nanostructures with diameters of 50-500 nm do not readily penetrate the cell membrane, and rationally optimizing nanoprobes for cell penetration requires real-time characterization methods that are capable of following the process of membrane penetration with nanometer resolution. Although extensive work has examined the rupture of supported synthetic lipid bilayers, little is known about the applicability of these model systems to living cell membranes with complex lipid compositions, cytoskeletal attachment, and membrane proteins. Here, we describe atomic force microscopy (AFM) membrane penetration experiments in two parallel systems: live HEK293 cells and stacks of synthetic lipid bilayers. By using the same probes in both systems, we were able to clearly identify membrane penetration in synthetic bilayers and compare these events with putative membrane penetration events in cells. We examined membrane penetration forces for three tip geometries and 18 chemical modifications of the probe surface, and in all cases the median forces required to penetrate cellular and synthetic lipid bilayers with nanoprobes were greater than 1 nN. The penetration force was sensitive to the probe's sharpness, but not its surface chemistry, and the force did not depend on cell surface or cytoskeletal properties, with cells and lipid stacks yielding similar forces. This systematic assessment of penetration under various mechanical and chemical conditions provides insights into nanoprobe-cell interactions and informs the design of future intracellular nanoprobes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.