Evidence map›Paper›PMID 25408802›Full record

ArticleCanadian Urological Association journal = Journal de l'Association des urologues du Canada2014

Assessing radiation exposure during endoscopic-guided percutaneous nephrolithotomy.

Andrea G Lantz, Padraic O'Malley, Michael Ordon, Jason Y Lee

Abstract read
In one paragraph

Article in Canadian Urological Association journal = Journal de l'Association des urologues du Canada, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Andrea G LantzDepartment of Urology, Dalhousie University, Halifax, NS;
Padraic O'MalleyDivision of Urology, Department of Surgery, St. Michael's Hospital, University of Toronto, Toronto, ON.
Michael OrdonDivision of Urology, Department of Surgery, St. Michael's Hospital, University of Toronto, Toronto, ON.
Jason Y LeeDivision of Urology, Department of Surgery, St. Michael's Hospital, University of Toronto, Toronto, ON.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionPercutaneous nephrolithotomy (PCNL) may be associated with significant ionizing radiation exposure for patients and operating room staff. Endoscopic-guided PCNL (ePCNL) is a technique that may be associated with less radiation exposure. This study examines ePCNL-related radiation exposure (fluoroscopy time, effective dose) and investigates variables that may predict increased exposure.

methodsA retrospective review of all consecutive ePCNLs performed at our institution, by a single surgeon, was conducted between November 2011 and November 2013. Patient demographics, stone characteristics and perioperative details were recorded, including radiation exposure. Pearson and Spearman correlation were used to assess variables correlated with radiation exposure.

resultsIn total, 55 ePCNL cases were included in the study. The mean age was 60 ± 15 years, mean body mass index (BMI) 30.0 ± 6.4 kg/m(2) and mean stone size 3.2 × 2.1 cm. Seven cases (13%) involved complete staghorn stones, and 69% involved supracostal punctures. The mean fluoroscopy time was 3.4 ± 2.3 minutes, mean ED 2.4 ± 1.9 mSv. The treatment success rate, assessed 1-week postoperatively, was 87.3% and 7.3% of cases required ancillary procedures. The overall complication rate was 29%, but only 3 cases (5.5%) were Clavien ≥3. Longer fluoroscopy time correlated with increased stone size (p < 0.01), longer operative time (p < 0.01) and lower treatment success rates (p < 0.01); higher effective dose correlated with longer fluoroscopy time (p < 0.01) and increased skin-to-stone distance (p < 0.01). BMI did not correlate with fluoroscopy time or effective dose.

conclusionsOutcomes of ePCNL are comparable to traditional PCNL techniques and may be associated with lower radiation exposure, particularly beneficial for patients with higher BMI.

Identifiers

PMID25408802
PMCPMC4216293

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.