Evidence map›Paper›PMID 25407570›Full record

Observational studyCritical care (London, England)2014

Dynamic arterial elastance as a predictor of arterial pressure response to fluid administration: a validation study.

Manuel Ignacio Monge García, Manuel Gracia Romero, Anselmo Gil Cano, Hollmann D Aya, Andrew Rhodes, Robert Michael Grounds, Maurizio Cecconi

2 registry-linked trialsOpen access · goldAbstract readObservational StudyValidation Study
In one paragraph

Observational study in Critical care (London, England), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 41 papers.

0numbers the graph read from it
0cells of the map it votes in
41citing papers in PubMed
6.5field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03179215 completednot on this mapstarted 2017, after this paper: background citation

Dynamic Arterial Elastance as a Predictor of Arterial Blood Pressure Response to Fluid Administration in Septic Patients

TypeobservationalSponsorCairo UniversityRan2017 to 2018Enrolled58ConditionsSepsisArmsfluid challange
NCT06461390 phase2 / phase3completednot on this mapstarted 2024, after this paper: background citation

The Effect of Fluid Loading With Early Norepinephrine Administration on Stroke Volume Index, Cardiac Index, Lactate, and Arterial Elastance in Pediatric Septic Shock

TypeinterventionalSponsorIndonesia UniversityRan2024 to 2024Enrolled42ConditionsSeptic Shock, SepsisArmsNorepinephrine, Ringer's Lactate
3 · Its place in the literature

Who cites it

41 citing papers in PubMed, 102 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Observational
  5. Observational
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Goal-directed Fluid Therapy in Neurosurgery: Three Feet from Gold?Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2023
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Effective hemodynamic monitoring.Critical care (London, England) · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Manuel Ignacio Monge GarcíaServicio de Cuidados Intensivos y Urgencias, Hospital SAS de Jerez, C/Circunvalación s/n, 11407, Jerez de la Frontera, Spain. ignaciomonge@gmail.com.
Manuel Gracia RomeroServicio de Cuidados Intensivos y Urgencias, Hospital SAS de Jerez, C/Circunvalación s/n, 11407, Jerez de la Frontera, Spain. manuel.graciaromero@hotmail.com.
Anselmo Gil CanoServicio de Cuidados Intensivos y Urgencias, Hospital SAS de Jerez, C/Circunvalación s/n, 11407, Jerez de la Frontera, Spain. anselgil@gmail.com.
Hollmann D AyaDepartment of Intensive Care Medicine, St George's Healthcare NHS Trust and St George's University of London, Blackshaw Road, Tooting, London, SW17 0QT, UK. hollmann.aya@nhs.net.
Andrew RhodesDepartment of Intensive Care Medicine, St George's Healthcare NHS Trust and St George's University of London, Blackshaw Road, Tooting, London, SW17 0QT, UK. andyr@sgul.ac.uk.
Robert Michael GroundsDepartment of Intensive Care Medicine, St George's Healthcare NHS Trust and St George's University of London, Blackshaw Road, Tooting, London, SW17 0QT, UK. michael.grounds@stgeorges.nhs.uk.
Maurizio CecconiDepartment of Intensive Care Medicine, St George's Healthcare NHS Trust and St George's University of London, Blackshaw Road, Tooting, London, SW17 0QT, UK. m.cecconi@nhs.net.
Hospital Jerez Puerta del Sur · ESSt George’s University Hospitals NHS Foundation Trust · GBSt George's, University of London · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionFunctional assessment of arterial load by dynamic arterial elastance (Eadyn), defined as the ratio between pulse pressure variation (PPV) and stroke volume variation (SVV), has recently been shown to predict the arterial pressure response to volume expansion (VE) in hypotensive, preload-dependent patients. However, because both SVV and PPV were obtained from pulse pressure analysis, a mathematical coupling factor could not be excluded. We therefore designed this study to confirm whether Eadyn, obtained from two independent signals, allows the prediction of arterial pressure response to VE in fluid-responsive patients.

methodsWe analyzed the response of arterial pressure to an intravenous infusion of 500 ml of normal saline in 53 mechanically ventilated patients with acute circulatory failure and preserved preload dependence. Eadyn was calculated as the simultaneous ratio between PPV (obtained from an arterial line) and SVV (obtained by esophageal Doppler imaging). A total of 80 fluid challenges were performed (median, 1.5 per patient; interquartile range, 1 to 2). Patients were classified according to the increase in mean arterial pressure (MAP) after fluid administration in pressure responders (≥ 10%) and non-responders.

resultsThirty-three fluid challenges (41.2%) significantly increased MAP. At baseline, Eadyn was higher in pressure responders (1.04 ± 0.28 versus 0.60 ± 0.14; P < 0.0001). Preinfusion Eadyn was related to changes in MAP after fluid administration (R (2) = 0.60; P < 0.0001). At baseline, Eadyn predicted the arterial pressure increase to volume expansion (area under the receiver operating characteristic curve, 0.94; 95% confidence interval (CI): 0.86 to 0.98; P < 0.0001). A preinfusion Eadyn value ≥ 0.73 (gray zone: 0.72 to 0.88) discriminated pressure responder patients with a sensitivity of 90.9% (95% CI: 75.6 to 98.1%) and a specificity of 91.5% (95% CI: 79.6 to 97.6%).

conclusionsFunctional assessment of arterial load by Eadyn, obtained from two independent signals, enabled the prediction of arterial pressure response to fluid administration in mechanically ventilated, preload-dependent patients with acute circulatory failure.

Indexed as

AgedArterial PressureBlood Flow VelocityCardiac OutputFemaleFluid TherapyHumansMaleMiddle AgedPredictive Value of TestsProspective StudiesRespiration, ArtificialStroke Volume

Identifiers

PMID25407570
PMCPMC4271484
OpenAlexW2151066923

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.