ArticleIndian journal of orthopaedics2014
Short term outcome of posterior dynamic stabilization system in degenerative lumbar diseases.
Article in Indian journal of orthopaedics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 3 syntheses or guidelines pooled it, 32 citations in OpenAlex.
- Medium and long-term radiographic and clinical outcomes of Dynesys dynamic stabilization versus instrumented fusion for degenerative lumbar spine diseases.BMC surgery · 2023Pooled it
- Dynesys system vs posterior decompression and fusion for the treatment of lumbar degenerative diseases.Medicine · 2020Pooled it
- Clinical and biomechanical researches of polyetheretherketone (PEEK) rods for semi-rigid lumbar fusion: a systematic review.Neurosurgical review · 2018Pooled it
- The Limited Evidence Base for Multilevel Lumbar Interbody Fusion and Its Consequences for Clinical Conclusions: A Systematic Review.Journal of clinical medicine · 2026Review
- Use of Dynamic Spinal Instruments (Dynesys) in Adult Spinal Deformities According to Silva-Lenke and Berjano-Lamartina Classifications.Diagnostics (Basel, Switzerland) · 2024Article
- Biomechanical Effect of Hybrid Dynamic Stabilization Implant on the Segmental Motion and Intradiscal Pressure in Human Lumbar Spine.Bioengineering (Basel, Switzerland) · 2022Article
- Effectiveness of dynamic fixation Coflex treatment for degenerative lumbar spinal stenosis.Experimental and therapeutic medicine · 2018Article
- Medium-term effects of Dynesys dynamic stabilization versus posterior lumbar interbody fusion for treatment of multisegmental lumbar degenerative disease.The Journal of international medical research · 2017Article
- The influence of L4-S1 Dynesys® dynamic stabilization versus fusion on lumbar motion and its relationship with lumbar degeneration: a retrospective study.Journal of orthopaedic surgery and research · 2017Article
- Short-term effects of a dynamic neutralization system (Dynesys) for multi-segmental lumbar disc herniation.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2016Article
- Clinical experiences of dynamic stabilizers: Dynesys and Dynesys top loading system for lumbar spine degenerative disease.The Kaohsiung journal of medical sciences · 2016Article
- Adjacent level disease following lumbar spine surgery: A review.Surgical neurology international · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundDecompression and fusion is considered as the 'gold standard' for the treatment of degenerative lumbar diseases, however, many disadvantages have been reported in several studies, recently like donor site pain, pseudoarthrosis, nonunion, screw loosening, instrumentation failure, infection, adjacent segment disease (ASDis) and degeneration. Dynamic neutralization system (Dynesys) avoids many of these disadvantages. This system is made up of pedicle screws, polyethylene terephthalate cords, and polycarbonate urethane spacers to stabilize the functional spinal unit and preserve the adjacent motion after surgeries. This was a retrospective cohort study to compare the effect of Dynesys for treating degenerative lumbar diseases with posterior lumbar interbody fusion (PLIF) based on short term followup. MATERIALS AND
methodsSeventy five consecutive patients of lumbar degenerative disease operated between October 2010 and November 2012 were studied with a minimum followup of 2 years. Patients were divided into two groups according to the different surgeries. 30 patients underwent decompression and implantation of Dynesys in two levels (n = 29) or three levels (n = 1) and 45 patients underwent PLIF in two levels (n = 39) or three levels (n = 6). Clinical and radiographic outcomes between two groups were reviewed.
resultsThirty patients (male:17, female:13) with a mean age of 55.96 ± 7.68 years were included in Dynesys group and the PLIF group included 45 patients (male:21, female:24) with a mean age of 54.69 ± 3.26 years. The average followup in Dynesys group and PLIF group was 2.22 ± 0.43 year (range 2-3.5 year) and 2.17 ± 0.76 year (range 2-3 year), respectively. Dynesys group showed a shorter operation time (141.06 ± 11.36 min vs. 176.98 ± 6.72 min, P < 0.001) and less intraoperative blood loss (386.76 ± 19.44 ml vs. 430.11 ± 24.72 ml, P < 0.001). For Dynesys group, visual analogue scale (VAS) for back and leg pain improved from 6.87 ± 0.80 to 2.92 ± 0.18 and 6.99 ± 0.81 to 3.25 ± 0.37, (both P < 0.001) and for PLIF, VAS for back and leg pain also improved significantly (6.97 ± 0.84-3.19 ± 0.19 and 7.26 ± 0.76-3.56 ± 0.38, both P < 0.001). Significant improvement was found at final followup in both groups in Oswestry disability index (ODI) score (both P < 0.001). Besides, Dynesys group showed a greater improvement in ODI and VAS back and leg pain scores compared with the PLIF group (P < 0.001, P = 0.009 and P = 0.031, respectively). For radiological, height of the operated level was found increased in both groups (both P < 0.001), but there was no difference between two groups (P = 0.93). For range of motion (ROM) of operated level, significant decrease was found in both groups (P < 0.001), but Dynesys showed a higher preservation of motion at the operative levels (P < 0.001). However, no significant difference was found in the percentage change of ROM of adjacent levels between Dynesys and PLIF (0.74 ± 8.92% vs. 0.92 ± 4.52%, P = 0.91). Some patients suffered from degeneration of adjacent intervertebral disc at final followup, but there was no significant difference in adjacent intervertebral disc degeneration between two groups (P = 0.71). Moreover, there were no differences in complications between Dynesys and PLIF (P = 0.90), although the incidence of complication in Dynesys was lower than PLIF (16.67% vs. 17.78%).
conclusionDynamic stabilization system treating lumbar degenerative disease showed clinical benefits with motion preservation of the operated segments, but does not have the significant advantage on motion preservation at adjacent segments, to avoid the degeneration of adjacent intervertebral disk.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.