Evidence map›Paper›PMID 25403763›Full record

Observational studyNeurocritical care2015

Feasibility and diagnostic accuracy of early electrophysiological recordings for ICU-acquired weakness: an observational cohort study.

Luuk Wieske, Camiel Verhamme, Esther Witteveen, Aline Bouwes, Daniela S Dettling-Ihnenfeldt, Marike van der Schaaf, Marcus J Schultz, Ivo N van Schaik, Janneke Horn

Open access · greenAbstract readObservational Study
PubMed Publisher
In one paragraph

Observational study in Neurocritical care, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 21 citations in OpenAlex.

  1. Trial
  2. Article
  3. Review
  4. Review
  5. Article
  6. Observational
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Luuk WieskeDepartment of Intensive Care Medicine, Academic Medical Center, University of Amsterdam, Meibergdreef 9, room C3-311, PO box 22700, 1105 AZ, Amsterdam, The Netherlands, l.wieske@amc.uva.nl.
Camiel Verhamme
Esther Witteveen
Aline Bouwes
Daniela S Dettling-Ihnenfeldt
Marike van der Schaaf
Marcus J Schultz
Ivo N van Schaik
Janneke Horn
Academic Medical Center · NLUniversity of Amsterdam · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAn early diagnosis of ICU-acquired weakness (ICU-AW) is difficult because disorders of consciousness frequently preclude muscle strength assessment. In this study, we investigated feasibility and accuracy of electrophysiological recordings to diagnose ICU-AW early in non-awake critically ill patients.

methodsNewly admitted patients, mechanically ventilated ≥2 days and unreactive to verbal stimuli, were included in this study. Electrophysiological recordings comprised nerve conduction studies (NCS) of three nerves and, if coagulation was normal, myography in three muscles. Upon awakening, strength was assessed (ICU-AW: average Medical Research Council score <4), blinded for electrophysiological recordings. Feasibility was expressed as the percentage of recordings that were both possible and had sufficient technical quality. Diagnostic accuracy of feasible (i.e., feasibility >75 %) recordings was analyzed based on cut-off values from healthy controls and from critically ill patients with and without ICU-AW.

resultsThirty-five patients were included (17 with ICU-AW). Recordings were obtained on day 4 (IQR: 3-6). Feasibility was acceptable for ulnar and peroneal nerve recordings, and low for sural recordings and myography. Diagnostic accuracy based on cut-off values from healthy controls was low. When using cut-off values from critically ill patients with and without ICU-AW, the peroneal compound muscle action potential amplitude and ulnar sensory nerve action potential amplitude had good diagnostic accuracy.

conclusionNerve conduction studies of the ulnar and peroneal nerve are feasible in critically ill patients. The diagnostic accuracy is low using cut-off values from healthy controls. Cut-off values validated specifically for discrimination between critically ill patients with and without ICU-AW may improve diagnostic accuracy.

Indexed as

Critical CareAction PotentialsCohort StudiesElectromyographyFeasibility StudiesFemaleHumansMaleMiddle AgedMuscle WeaknessNeural ConductionSensitivity and Specificity

Identifiers

PMID25403763
OpenAlexW2115827551

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.