ArticleRadiation and environmental biophysics2015
Automatic versus manual lymphocyte fixation: impact on dose estimation using the cytokinesis-block micronucleus assay.
Article in Radiation and environmental biophysics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Cytogenetic biological dosimetry assays: recent developments and updates.Radiation oncology journal · 2021Article
- The use of a centrifuge-free RABiT-II system for high-throughput micronucleus analysis.Journal of radiation research · 2020Article
- RABiT-II: A Fully-Automated Micronucleus Assay System with Shortened Time to Result.Radiation research · 2019Article
- RABiT-II: Implementation of a High-Throughput Micronucleus Biodosimetry Assay on Commercial Biotech Robotic Systems.Radiation research · 2017Article
- Development of a High-Throughput and Miniaturized Cytokinesis-Block Micronucleus Assay for Use as a Biological Dosimetry Population Triage Tool.Radiation research · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The lymphocyte cytokinesis-block micronucleus (CBMN) assay is a biodosemeter for the exposure to ionizing radiation. We examined the feasibility to implement a fully automated cell harvesting system for binucleate lymphocyte (BN) fixation. We compared fully automated versus manual BN fixation and evaluated its relevance on the accuracy of dose estimates using the CBMN. First, dose-response curves based on X-ray irradiated blood samples of ten healthy donors (0-4 Gy, dose rate 1.0 Gy/min) were established. BN was either prepared manually or fully automatically using the Hanabi cell harvester system PII. Slides were finally scored following an automatic or semi-automatic approach using the Metafer4 platform. The variance was calculated per dose and separately for each of the four fixation and scoring combinations. Thereafter, a serial of 16 blood samples of unknown exposure doses (0-3.9 Gy X-ray) was analyzed. Employing the four fixation and scoring combinations, we compared the number of dose estimates lying outside the ±0.5 Gy interval and the mean absolute difference (MAD) and examined sensitivity, specificity and accuracy of doses merged into binary dose categories of clinical significance. Irrespective of the fixation procedure, we observed at doses ≤1.0 Gy about 2-4 times higher median variances for the automated scoring procedure over the semi-automated approach (p ≤ 0.03). The lowest median variance was observed for automatic fixation + semi-automated scoring (135) which was even 2 times lower relative to manual fixation + semi-automated scoring (276, p = 0.04). These differences became negligible after doses >1.0 Gy. For the automatic fixation procedure, we also observed a tendency toward borderline significant higher numbers of dose estimates falling into the ±0.5 Gy interval (25 %, p = 0.08) and lower MAD values (50 %, p = 0.09), which was predominantly caused by the accuracy of dose assessment >1.0 Gy. Regarding the discrimination of binary dose categories of clinical significance, we observed a good agreement of both fixation procedures. The implementation of the automatic cell harvesting system considerably reduces the workload and results in dose estimates with a tendency of being slightly more accurate as they are after a manual fixation.