Evidence map›Paper›PMID 25398412›Full record

ArticleBMC infectious diseases2014

Mold contamination in a controlled hospital environment: a 3-year surveillance in southern Italy.

Giuseppina Caggiano, Christian Napoli, Caterina Coretti, Grazia Lovero, Giancarlo Scarafile, Osvalda De Giglio, Maria Teresa Montagna

Open access · goldAbstract read
In one paragraph

Article in BMC infectious diseases, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed, 57 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Observational
  11. Article
  12. Impact of Fungal Spores on Asthma Prevalence and Hospitalization.International journal of molecular sciences · 2022
    Review
  13. Article
  14. Article
  15. Microbial Air Quality in Healthcare Facilities.International journal of environmental research and public health · 2021
    Review
  16. Evaluation of Rhodotorula spp. contamination in hospital environments.Environmental monitoring and assessment · 2021
    Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Giuseppina Caggiano
Christian Napoli
Caterina Coretti
Grazia Lovero
Giancarlo Scarafile
Osvalda De Giglio
Maria Teresa Montagna
University of Bari Aldo Moro · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEnvironmental monitoring of airborne filamentous fungi is necessary to reduce fungal concentrations in operating theaters and in controlled environments, and to prevent infections. The present study reports results of a surveillance of filamentous fungi carried out on samples from air and surfaces in operating theaters and controlled environments in an Italian university hospital.

methodsSampling was performed between January 2010 and December 2012 in 32 operating theaters and five departments with high-risk patients. Indoor air specimens were sampled using a microbiological air sampler; Rodac contact plates were used for surface sampling. Fungal isolates were identified at the level of genera and species.

resultsSixty-one samples (61/465; 13.1%) were positive for molds, with 18 from controlled environments (18/81; 22.2%) and 43 (43/384; 11.2%) from operating theaters. The highest air fungal load (AFL, colony-forming units per cubic meter [CFU/m(3)]) was recorded in the ophthalmology operating theater, while the pediatric onco-hematology ward had the highest AFL among the wards (47 CFU/m(3)). The most common fungi identified from culture of air specimens were Aspergillus spp. (91.8%), Penicillium spp., (6%) and Paecilomyces spp. (1.5%). During the study period, a statistically significant increase in CFU over time was recorded in air-controlled environments (p = 0.043), while the increase in AFL in operating theaters was not statistically significant (p = 0.145). Molds were found in 29.1% of samples obtained from surfaces. Aspergillus fumigatus was the most commonly isolated (68.5%).

conclusionsOur findings will form the basis for action aimed at improving the air and surface quality of these special wards. The lack of any genetic analysis prevented any correlation of fungal environmental contamination with onset of fungal infection, an analysis that will be undertaken in a prospective study in patients admitted to the same hospital.

Indexed as

Air MicrobiologyAspergillusEnvironmental MonitoringEquipment ContaminationHospitals, UniversityHumansItalyMycosesOperating RoomsProspective Studies

Identifiers

PMID25398412
PMCPMC4236478
OpenAlexW2037418066

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked