Evidence map›Paper›PMID 25397577›Full record

Trial reportPloS one2014

Suppression of enhanced physiological tremor via stochastic noise: initial observations.

Carlos Trenado, Florian Amtage, Frank Huethe, Jürgen Schulte-Mönting, Ignacio Mendez-Balbuena, Stuart N Baker, Mark Baker, Marie-Claude Hepp-Reymond, Elias Manjarrez, Rumyana Kristeva

Open access · goldAbstract readClinical Trial
In one paragraph

Trial report in PloS one, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 17 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 4 countries.

Carlos TrenadoDepartment of Neurology and Neurophysiology, University Freiburg, Freiburg, Germany.
Florian AmtageDepartment of Neurology and Neurophysiology, University Freiburg, Freiburg, Germany.
Frank HuetheDepartment of Neurology and Neurophysiology, University Freiburg, Freiburg, Germany.
Jürgen Schulte-MöntingInstitute for Medical Biometry and Medical Informatics, University Freiburg, Freiburg, Germany.
Ignacio Mendez-BalbuenaFacultad de Psicología, Benemérita Universidad Autónoma de Puebla, Puebla, México.
Stuart N BakerInstitute of Neuroscience, Newcastle University, Newcastle upon Tyne, United Kingdom.
Mark BakerInstitute of Neuroscience, Newcastle University, Newcastle upon Tyne, United Kingdom.
Marie-Claude Hepp-ReymondInstitute of Neuroinformatics, University of Zürich and ETH Zürich, Zurich, Switzerland.
Elias ManjarrezInstituto de Fisiología, Benemérita Universidad Autónoma de Puebla, Puebla, México.
Rumyana KristevaDepartment of Neurology and Neurophysiology, University Freiburg, Freiburg, Germany.
University of Freiburg · DEBenemérita Universidad Autónoma de Puebla · MXNewcastle University · GBUniversity of Zurich · CH

Funding

Medical Research CouncilWellcome Trust 101002
6 · The paper itself

Abstract

Enhanced physiological tremor is a disabling condition that arises because of unstable interactions between central tremor generators and the biomechanics of the spinal stretch reflex. Previous work has shown that peripheral input may push the tremor-related spinal and cortical systems closer to anti-phase firing, potentially leading to a reduction in tremor through phase cancellation. The aim of the present study was to investigate whether peripherally applied mechanical stochastic noise can attenuate enhanced physiological tremor and improve motor performance. Eight subjects with enhanced physiological tremor performed a visuomotor task requiring the right index finger to compensate a static force generated by a manipulandum to which Gaussian noise (3-35 Hz) was applied. The finger position was displayed on-line on a monitor as a small white dot which the subjects had to maintain in the center of a larger green circle. Electromyogram (EMG) from the active hand muscles and finger position were recorded. Performance was measured by the mean absolute deviation of the white dot from the zero position. Tremor was identified by the acceleration in the frequency range 7-12 Hz. Two different conditions were compared: with and without superimposed noise at optimal amplitude (determined at the beginning of the experiment). The application of optimum noise reduced tremor (accelerometric amplitude and EMG activity) and improved the motor performance (reduced mean absolute deviation from zero). These data provide the first evidence of a significant reduction of enhanced physiological tremor in the human sensorimotor system due to application of external stochastic noise.

Indexed as

AdultAnalysis of VarianceElectromyographyFeedback, SensoryFemaleHumansMalePhotic StimulationPhysical StimulationPsychomotor PerformanceStochastic ProcessesTremor

Identifiers

PMID25397577
PMCPMC4232445
OpenAlexW2067735624

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.