Evidence map›Paper›PMID 25395364›Full record

ArticleThe international journal of cardiovascular imaging2015

Evaluation of IVOCT imaging of coronary artery metallic stents with neointimal coverage.

Sahar Elahi, Derek Ho, Marc D Feldman, Jouke Dijkstra, Thomas E Milner

Open access · hybridAbstract readComparative StudyEvaluation Study
In one paragraph

Article in The international journal of cardiovascular imaging, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Cardiovascular imaging 2015 in the International Journal of Cardiovascular Imaging.The international journal of cardiovascular imaging · 2016
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Sahar ElahiDepartment of Biomedical Engineering, University of Texas at Austin, 107 W Dean Keeton Street Stop C0800, Austin, TX, 78712, USA, sahar.elahi@gmail.com.
Derek Ho
Marc D Feldman
Jouke Dijkstra
Thomas E Milner
The University of Texas at Austin · USLeiden University Medical Center · NLThe University of Texas Health Science Center at San Antonio · US

Funding

Training in Medical ImagingT32EB001040 · NIBIB · DUKE UNIVERSITY · PI NIGHTINGALE, KATHRYN RADABAUGH · 2003 to 2018
$4.4M
NIBIB NIH HHS T32 EB001040
6 · The paper itself

Abstract

Accuracy of IVOCT for measurement of neointimal thickness and effect of neointima in the appearance of metallic struts in IVOCT images was investigated. Phantom vessels were constructed and coronary stents were deployed and covered with thick (250-400 μm) and thin (30-70 μm) phantom neointima. High resolution Micro-CT images of the stent struts were recorded as a gold standard. IVOCT images of the phantom vessels were acquired with various luminal blood scattering strengths and measured neointimal thicknesses from IVOCT and Micro-CT images were compared. In transparent lumen, comparison of IVOCT and Micro-CT neointima thickness measurements found no significant difference (p > 0.05) in the thick neointima phantom but a significant difference (p < 0.05) in the thin neointima phantom. For both thick and thin neointima, IVOCT neointimal thickness measurements varied from Micro-CT values by as much as ±35%. Increased luminal scattering due to presence of blood at concentrations <5% did not interfere with measurement of thin neointimas and was validated by ANOVA analysis (p = 0.95). IV-OCT measurement of strut feature size with an overlying thin neointima match true values determined with Micro-CT (p = 0.82). Presence of a thick neointima resulted in lateral elongation or merry-go-rounding of stent strut features in IVOCT images. Phantom IVOCT images suggest that thick neointimal layers can result in more than 40 % lateral elongation of stent strut features. Simulated IVOCT images of metallic stent struts with varying neointimal thickness suggest that neointimal light scattering can introduce the merry-go-round effect.

Indexed as

MetalsNeointimaStentsTomography, Optical CoherenceCoronary AngiographyCoronary Artery DiseaseCoronary VesselsHumansModels, CardiovascularPercutaneous Coronary InterventionPhantoms, ImagingPredictive Value of TestsProsthesis DesignReproducibility of ResultsX-Ray MicrotomographyMetals

Identifiers

PMID25395364
PMCPMC4368839
OpenAlexW2163452772

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.