Evidence map›Paper›PMID 25385003›Full record

ArticleInternational orthopaedics2015

High incidence of stem loosening in association with periprosthetic femur fractures in previously well-fixed cementless grit-blasted tapered-wedge stems.

Seung-Jae Lim, Kyung-Jae Lee, Byung-Woo Min, Joo-Hyoun Song, Sang-Yeon So, Youn-Soo Park

Abstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Seung-Jae LimDepartment of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710, South Korea.
Kyung-Jae Lee
Byung-Woo Min
Joo-Hyoun Song
Sang-Yeon So
Youn-Soo Park

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePeriprosthetic femur fracture is a potentially worrisome phenomenon for cementless stem fixation. The aim of this study was to document the incidence of stem loosening following periprosthetic femur fracture in previously well-fixed cementless grit-blasted tapered-wedge stems.

methodsWe identified 36 periprosthetic femur fractures of either Vancouver B1 or B2 following hip arthroplasties using cementless grit-blasted tapered-wedge titanium stems at three participating institutions (GB group). The control group consisted of 21 periprosthetic femur fractures of either Vancouver B1 or B2 following hip arthroplasties using cementless proximal porous-coated stems at the same institutions during the same period of study (PC group). All femoral stems had been in a well-fixed state before occurrence of fracture. All patients were treated surgically and femoral stem stability was assessed using preoperative radiographs and confirmed by intraoperative scrutinization.

resultsSeven (19.4%) of 36 fractures were Vancouver B1 and 29 (80.6%) were Vancouver B2 in the GB group, whereas 18 (85.7%) of 21 fractures were Vancouver B1 and 3 (14.3%) were Vancouver B2 in the PC group (P < 0.0001). The odds ratio for stem loosening was 24.86 (95% CI, 5.69-108.63) in the GB group versus the PC group.

conclusionsHip arthroplasty using cementless grit-blasted tapered-wedge titanium stems showed higher incidence of stem loosening in association with periprosthetic femur fracture than hip arthroplasty conducted using proximal porous-coated stems. A high index of suspicion of stem loosening might be necessary in periprosthetic femur fracture following hip arthroplasty using this type of stems.

Indexed as

AdultAgedArthroplasty, Replacement, HipBiocompatible MaterialsFemaleFemoral FracturesHip ProsthesisHumansIncidenceMaleMiddle AgedPeriprosthetic FracturesProsthesis DesignProsthesis FailureRetrospective StudiesTitaniumBiocompatible MaterialsTitanium

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked