Evidence map›Paper›PMID 25381048›Full record

ArticleJournal of medical systems2014

Improving operating room turnover time: a systems based approach.

Ankeet S Bhatt, Grant W Carlson, Peter J Deckers

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical systems, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 1 pooled it
6.7field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 1 synthesis or guideline pooled it, 47 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Rapid standardized operating rooms (RAPSTOR) in thyroid and parathyroid surgery.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale · 2021
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Ankeet S BhattUniversity of Connecticut School of Medicine, 263 Farmington Ave, Farmington, CT, 06032, USA, abhatt@student.uchc.edu.
Grant W Carlson
Peter J Deckers
University of Connecticut · USEmory University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Operating room (OR) turnover time (TT) has a broad and significant impact on hospital administrators, providers, staff and patients. Our objective was to identify current problems in TT management and implement a consistent, reproducible process to reduce average TT and process variability. Initial observations of TT were made to document the existing process at a 511 bed, 24 OR, academic medical center. Three control groups, including one consisting of Orthopedic and Vascular Surgery, were used to limit potential confounders such as case acuity/duration and equipment needs. A redesigned process based on observed issues, focusing on a horizontally structured, systems-based approach has three major interventions: developing consistent criteria for OR readiness, utilizing parallel processing for patient and room readiness, and enhancing perioperative communication. Process redesign was implemented in Orthopedics and Vascular Surgery. Comparisons of mean and standard deviation of TT were made using an independent 2-tailed t-test. Using all surgical specialties as controls (n = 237), mean TT (hh:mm:ss) was reduced by 0:20:48 min (95 % CI, 0:10:46-0:30:50), from 0:44:23 to 0:23:25, a 46.9 % reduction. Standard deviation of TT was reduced by 0:10:32 min, from 0:16:24 to 0:05:52 and frequency of TT≥30 min was reduced from 72.5to 11.7 %. P < 0.001 for each. Using Vascular and Orthopedic surgical specialties as controls (n = 13), mean TT was reduced by 0:15:16 min (95 % CI, 0:07:18-0:23:14), from 0:38:51 to 0:23:35, a 39.4 % reduction. Standard deviation of TT reduced by 0:08:47, from 0:14:39 to 0:05:52 and frequency of TT≥30 min reduced from 69.2 to 11.7 %. P < 0.001 for each. Reductions in mean TT present major efficiency, quality improvement, and cost-reduction opportunities. An OR redesign process focusing on parallel processing and enhanced communication resulted in greater than 35 % reduction in TT. A systems-based focus should drive OR TT design.

Indexed as

Efficiency, OrganizationalHumansOperating RoomsSystems AnalysisTime and Motion StudiesTime Management

Identifiers

PMID25381048
OpenAlexW2008401939

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.