ArticleTissue engineering. Part C, Methods2015
Tissue-engineered heart valve with a tubular leaflet design for minimally invasive transcatheter implantation.
Article in Tissue engineering. Part C, Methods, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
25 citing papers in PubMed, 71 citations in OpenAlex.
- Manufacturing Silk Fibroin Hollow Nanoyarns as Fundamental Units for Advanced Medical Textiles.ACS applied materials & interfaces · 2026Article
- A Versatile Engineering Platform for the Fabrication of Prosthetic Venous Valves Using Electrospinning.Advanced healthcare materials · 2026Article
- Small patients - Big needs: A material-based approach to develop miniaturised valves for congenital heart diseases.Bioactive materials · 2026Article
- Dehydrated silk fibroin matrices as versatile delivery systems for extracellular vesicles.Frontiers in bioengineering and biotechnology · 2026Article
- Bioorthogonal Mussel-Inspired Elastin-like Nanocoatings for Indwelling Devices.ACS applied materials & interfaces · 2025Article
- Biohybrid Vascular Graft Made of Textile-Reinforced Elastin-Like Recombinamers and Its Preservation via Drying Processes.Advanced healthcare materials · 2025Article
- Novel Bioreactor Design for Non-invasive Longitudinal Monitoring of Tissue-Engineered Heart Valves in 7T MRI and Ultrasound.Annals of biomedical engineering · 2025Article
- Elastic, load-bearing and autoclavable protein-based graft for coronary revascularization.Frontiers in bioengineering and biotechnology · 2025Article
- A Dexamethasone-Loaded Polymeric Electrospun Construct as a Tubular Cardiovascular Implant.Polymers · 2023Article
- Strategies for Development of Synthetic Heart Valve Tissue Engineering Scaffolds.Progress in materials science · 2023Article
- Bio-Inspired Fiber Reinforcement for Aortic Valves: Scaffold Production Process and Characterization.Bioengineering (Basel, Switzerland) · 2023Article
- Influence of Diameter and Cyclic Mechanical Stimulation on the Beating Frequency of Myocardial Cell-Laden Fibers.Gels (Basel, Switzerland) · 2023Article
- Bioglues Based on an Elastin-Like Recombinamer: Effect of Tannic Acid as an Additive on Tissue Adhesion and Cytocompatibility.International journal of molecular sciences · 2023Article
- Silk Fibroin as Adjuvant in the Fabrication of Mechanically Stable Fibrin Biocomposites.Polymers · 2022Article
- Natural Polymers in Heart Valve Tissue Engineering: Strategies, Advances and Challenges.Biomedicines · 2022Review
- Biohybrid elastin-like venous valve with potential forFrontiers in bioengineering and biotechnology · 2022Article
- De Novo Valve Tissue Morphology Following Bioscaffold Mitral Valve Replacement in a Juvenile Non-Human Primate Model.Bioengineering (Basel, Switzerland) · 2021Article
- Melt Electrowriting of Complex 3D Anatomically Relevant Scaffolds.Frontiers in bioengineering and biotechnology · 2020Article
- Small Caliber Compliant Vascular Grafts Based on Elastin-Like Recombinamers forFrontiers in bioengineering and biotechnology · 2019Article
- Intramyocardial angiogenetic stem cells and epicardial erythropoietin save the acute ischemic heart.Disease models & mechanisms · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Transcatheter aortic valve implantation of (nonviable) bioprosthetic valves has been proven a valid alternative to conventional surgical implantation in patients at high or prohibitive mortality risk. In this study we present the in vitro proof-of-principle of a newly developed tissue-engineered heart valve for minimally invasive implantation, with the ultimate aim of adding the unique advantages of a living tissue with regeneration capabilities to the continuously developing transcatheter technologies. The tube-in-stent is a fibrin-based tissue-engineered valve with a tubular leaflet design. It consists of a tubular construct sewn into a self-expandable nitinol stent at three commissural attachment points and along a circumferential line so that it forms three coaptating leaflets by collapsing under diastolic back pressure. The tubular constructs were molded with fibrin and human umbilical vein cells. After 3 weeks of conditioning in a bioreactor, the valves were fully functional with unobstructed opening (systolic phase) and complete closure (diastolic phase). Tissue analysis showed a homogeneous cell distribution throughout the valve's thickness and deposition of collagen types I and III oriented along the longitudinal direction. Immunohistochemical staining against CD31 and scanning electron microscopy revealed a confluent endothelial cell layer on the surface of the valves. After harvesting, the valves underwent crimping for 20 min to simulate the catheter-based delivery. This procedure did not affect the valvular functionality in terms of orifice area during systole and complete closure during diastole. No influence on the extracellular matrix organization, as assessed by immunohistochemistry, nor on the mechanical properties was observed. These results show the potential of combining tissue engineering and minimally invasive implantation technology to obtain a living heart valve with a simple and robust tubular design for transcatheter delivery. The effect of the in vivo remodeling on the functionality of the tube-in-stent valve remains to be tested.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.