Evidence map›Paper›PMID 25380414›Full record

ArticleTissue engineering. Part C, Methods2015

Tissue-engineered heart valve with a tubular leaflet design for minimally invasive transcatheter implantation.

Ricardo Moreira, Thaddaeus Velz, Nuno Alves, Valentine N Gesche, Axel Malischewski, Thomas Schmitz-Rode, Julia Frese, Stefan Jockenhoevel, Petra Mela

Open access · hybridAbstract read
In one paragraph

Article in Tissue engineering. Part C, Methods, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
4.1field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed, 71 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Biohybrid elastin-like venous valve with potential forFrontiers in bioengineering and biotechnology · 2022
    Article
  17. Article
  18. Melt Electrowriting of Complex 3D Anatomically Relevant Scaffolds.Frontiers in bioengineering and biotechnology · 2020
    Article
  19. Small Caliber Compliant Vascular Grafts Based on Elastin-Like Recombinamers forFrontiers in bioengineering and biotechnology · 2019
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Ricardo Moreira1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.
Thaddaeus Velz1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.
Nuno Alves1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.
Valentine N Gesche2Institut für Textiltechnik, RWTH Aachen University, Aachen, Germany.
Axel Malischewski1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.
Thomas Schmitz-Rode1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.
Julia Frese1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.
Stefan Jockenhoevel1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.
Petra Mela1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.
RWTH Aachen University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Transcatheter aortic valve implantation of (nonviable) bioprosthetic valves has been proven a valid alternative to conventional surgical implantation in patients at high or prohibitive mortality risk. In this study we present the in vitro proof-of-principle of a newly developed tissue-engineered heart valve for minimally invasive implantation, with the ultimate aim of adding the unique advantages of a living tissue with regeneration capabilities to the continuously developing transcatheter technologies. The tube-in-stent is a fibrin-based tissue-engineered valve with a tubular leaflet design. It consists of a tubular construct sewn into a self-expandable nitinol stent at three commissural attachment points and along a circumferential line so that it forms three coaptating leaflets by collapsing under diastolic back pressure. The tubular constructs were molded with fibrin and human umbilical vein cells. After 3 weeks of conditioning in a bioreactor, the valves were fully functional with unobstructed opening (systolic phase) and complete closure (diastolic phase). Tissue analysis showed a homogeneous cell distribution throughout the valve's thickness and deposition of collagen types I and III oriented along the longitudinal direction. Immunohistochemical staining against CD31 and scanning electron microscopy revealed a confluent endothelial cell layer on the surface of the valves. After harvesting, the valves underwent crimping for 20 min to simulate the catheter-based delivery. This procedure did not affect the valvular functionality in terms of orifice area during systole and complete closure during diastole. No influence on the extracellular matrix organization, as assessed by immunohistochemistry, nor on the mechanical properties was observed. These results show the potential of combining tissue engineering and minimally invasive implantation technology to obtain a living heart valve with a simple and robust tubular design for transcatheter delivery. The effect of the in vivo remodeling on the functionality of the tube-in-stent valve remains to be tested.

Indexed as

BioprosthesisHeart Valve ProsthesisHeart Valve Prosthesis ImplantationMuscle, Smooth, VascularMyocytes, Smooth MuscleProsthesis DesignHumans

Identifiers

PMID25380414
PMCPMC4442597
OpenAlexW2027495896

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked