ArticleEuropean journal of applied physiology2015
Contracting biceps brachii elastic properties can be reliably characterized using supersonic shear imaging.
Article in European journal of applied physiology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Shear wave elastography characteristics of the gastrocnemius muscle in postural instability gait disorder vs tremor dominant Parkinson's disease patients.Acta neurologica Belgica · 2024Article
- Load sharing between synergistic muscles characterized by a ligand-binding approach and elastography.Scientific reports · 2023Article
- Verification of surface electromyographic activity of the oblique externus abdominis using ultrasound shear wave elastography.Physiological reports · 2022Article
- Surface wave elastography is a reliable method to correlate muscle elasticity, torque, and electromyography activity level.Physiological reports · 2021Article
- Young's Modulus of Bilateral Infraspinatus Tendon Measured in Different Postures by Shear Wave Elastography Before and After Exercise.Orthopaedic surgery · 2021Article
- Hamstrings load bearing in different contraction types and intensities: A shear-wave and B-mode ultrasonographic study.PloS one · 2021Article
- Inter- and intra-reader reproducibility of shear wave elastography measurements for musculoskeletal soft tissue masses.Skeletal radiology · 2020Article
- Shear wave velocity is sensitive to changes in muscle stiffness that occur independently from changes in force.Journal of applied physiology (Bethesda, Md. : 1985) · 2020Article
- Hamstring stiffness pattern during contraction in healthy individuals: analysis by ultrasound-based shear wave elastography.European journal of applied physiology · 2018Article
- Can Shoulder Muscle Activity Be Evaluated With Ultrasound Shear Wave Elastography?Clinical orthopaedics and related research · 2018Article
- Shear wave sonoelastography of skeletal muscle: basic principles, biomechanical concepts, clinical applications, and future perspectives.Skeletal radiology · 2018Review
- Passive material properties of stroke-impaired plantarflexor and dorsiflexor muscles.Clinical biomechanics (Bristol, Avon) · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeSince experimental techniques classically used to investigate the mechanical behavior of muscle in vivo assess global mechanical properties of the musculo-articular complex, the aim of the present study was to assess the feasibility and reliability of localized contracting biceps brachii elastic properties' measurements using elastography.
methodsTwelve subjects participated in intra-session, inter-session and inter-observer reliability experiments. They were asked to perform a linear torque ramp of 30 s from 0 to 75 % of maximal voluntary contraction. Joint torque, electromyographic (EMG) activity and shear elastic modulus were synchronously measured in the biceps brachii. Elastic properties were determined by stiffness indexes calculated as the slopes of the linear regressions established between shear modulus and joint torque or EMG levels. Compliance indexes were also obtained by plotting logarithmic values of shear modulus versus torque or EMG.
resultsDetermination coefficients were high for the four relationships (0.87-0.94). In addition, reliability was significantly higher for the compliance index taking into account logarithmic values of EMG activity (mean coefficient of variation of 5.3 ± 4.1%; P = 0.003). Although not statistically different from other methods (P = 0.111), the mean intra-class correlation coefficient was excellent (0.98 ± 0.01) and the standard error in measurement very low (0.04 ± 0.01 for a mean index of -0.73 ± 0.28).
conclusionsBiceps brachii elastic properties can be reliably investigated during contraction via elastography using the proposed fitting method. Use of this technique could provide new insights into the understanding of localized muscle elastic properties adaptations.
Indexed as
Identifiers
25366254What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.