ArticlePhysics in medicine and biology2014

Simulation study comparing high-purity germanium and cadmium zinc telluride detectors for breast imaging.

D L Campbell, T E Peterson

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. An energy-optimized collimator design for a CZT-based SPECT camera.Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment · 2016
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

D L CampbellInstitute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA. Department of Physics and Astronomy, Vanderbilt University, Nashville, TN, USA.
T E Peterson
Vanderbilt University Medical Center · US

Funding

Training in Cellular and Molecular Imaging of CancerR25CA136440 · NCI · VANDERBILT UNIVERSITY · PI GORE, JOHN C · 2009 to 2013
$2.1M
Germanium Gamma CamerasR44EB015889 · NIBIB · PHDS COMPANY · PI HULL, ETHAN · 2012 to 2013
$977k
NCI NIH HHS R25 CA136440NCI NIH HHS R25CA136440NIBIB NIH HHS R44 EB015889NIBIB NIH HHS R44EB15889
6 · The paper itself

Abstract

We conducted simulations to compare the potential imaging performance for breast cancer detection with High-Purity Germanium (HPGe) and Cadmium Zinc Telluride (CZT) systems with 1% and 3.8% energy resolution at 140 keV, respectively. Using the Monte Carlo N-Particle (MCNP5) simulation package, we modelled both 5 mm-thick CZT and 10 mm-thick HPGe detectors with the same parallel-hole collimator for the imaging of a breast/torso phantom. Simulated energy spectra were generated, and planar images were created for various energy windows around the 140 keV photopeak. Relative sensitivity and scatter and the torso fractions were calculated along with tumour contrast and signal-to-noise ratios (SNR). Simulations showed that utilizing a ±1.25% energy window with an HPGe system better suppressed torso background and small-angle scattered photons than a comparable CZT system using a -5%/+10% energy window. Both systems provided statistically similar contrast and SNR, with HPGe providing higher relative sensitivity. Lowering the counts of HPGe images to match CZT count density still yielded equivalent contrast between HPGe and CZT. Thus, an HPGe system may provide equivalent breast imaging capability at lower injected radioactivity levels when acquiring for equal imaging time.

Indexed as

Phantoms, ImagingBreastCadmiumComputer SimulationFemaleGermaniumHumansImage Processing, Computer-AssistedMonte Carlo MethodPhotonsPositron-Emission TomographyRadionuclide ImagingSignal-To-Noise RatioTelluriumZincCadmiumCdZnTeGermaniumTelluriumZinc

Identifiers

PMID25360792
PMCPMC4237407
OpenAlexW2002529246

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.