ArticleAnalytical chemistry2014
Dielectrophoretic monitoring and interstrain separation of intact Clostridium difficile based on their S(Surface)-layers.
Article in Analytical chemistry, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 37 citations in OpenAlex.
- On-Chip Integration of Impedance Cytometry for Inline Optimization of Dielectrophoretic Separations on Multiple Cellular Biophysical Metrics.ACS sensors · 2025Article
- On-chip microfluidic buffer swap of biological samples in-line with downstream dielectrophoresis.Electrophoresis · 2022Article
- Modified Red Blood Cells as Multimodal Standards for Benchmarking Single-Cell Cytometry and Separation Based on Electrical Physiology.Analytical chemistry · 2022Article
- Minimum Bactericidal Concentration of Ciprofloxacin toSensors and actuators. B, Chemical · 2020Article
- High-throughput dynamical analysis of dielectrophoretic frequency dispersion of single cells based on deflected flow streamlines.Analytical and bioanalytical chemistry · 2020Article
- RapidACS infectious diseases · 2020Article
- Electrophysiology-based stratification of pancreatic tumorigenicity by label-free single-cell impedance cytometry.Analytica chimica acta · 2020Article
- Characterization of Simple and Double Yeast Cells Using Dielectrophoretic Force Measurement.Sensors (Basel, Switzerland) · 2019Article
- Single-cell electro-phenotyping for rapid assessment ofSensors and actuators. B, Chemical · 2018Article
- Cell Surface N-Glycans Influence Electrophysiological Properties and Fate Potential of Neural Stem Cells.Stem cell reports · 2018Article
- Analysis of the dielectrophoretic properties of cells using the isomotive AC electric field.Biomicrofluidics · 2018Article
- Label-Free Quantification of Intracellular Mitochondrial Dynamics Using Dielectrophoresis.Analytical chemistry · 2017Article
- Review: Microbial analysis in dielectrophoretic microfluidic systems.Analytica chimica acta · 2017Review
- Dielectrophoresis for Biomedical Sciences Applications: A Review.Sensors (Basel, Switzerland) · 2017Review
- Numerical Model of Streaming DEP for Stem Cell Sorting.Micromachines · 2016Article
- Tracking Inhibitory Alterations during InterstrainACS infectious diseases · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
Abstract
Clostridium difficile (C. difficile) infection (CDI) rates have exhibited a steady rise worldwide over the last two decades and the infection poses a global threat due to the emergence of antibiotic resistant strains. Interstrain antagonistic interactions across the host microbiome form an important strategy for controlling the emergence of CDI. The current diagnosis method for CDI, based on immunoassays for toxins produced by pathogenic C. difficile strains, is limited by false negatives due to rapid toxin degradation. Furthermore, simultaneous monitoring of nontoxigenic C. difficile strains is not possible, due to absence of these toxins, thereby limiting its application toward the control of CDI through optimizing antagonistic interstrain interactions. Herein, we demonstrate that morphological differences within the cell wall of particular C. difficile strains with differing S-layer proteins can induce systematic variations in their electrophysiology, due alterations in cell wall capacitance. As a result, dielectrophoretic frequency analysis can enable the independent fingerprinting and label-free separation of intact microbials of each strain type from mixed C. difficile samples. The sensitivity of this contact-less electrophysiological method is benchmarked against the immunoassay and microbial growth rate methods for detecting alterations within both, toxigenic and nontoxigenic C. difficile strains after vancomycin treatment. This microfluidic diagnostic platform can assist in the development of therapies for arresting clostridial infections by enabling the isolation of individual strains, optimization of antibiotic treatments and the monitoring of microbiomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.