Evidence map›Paper›PMID 25302002›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2014

Relative object detectability (ROD): a new metric for comparing x-ray image detector performance for a specified object of interest.

V Singh, A Jain, D R Bednarek, S Rudin

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. New Family of Generalized Metrics for Comparative Imaging System Evaluation.Proceedings of SPIE--the International Society for Optical Engineering · 2015
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

V SinghToshiba Stoke and Vascular Research Center, University at Buffalo (SUNY), Clinical Translational Research Center, 8 floor, 875 Ellicott Street, Buffalo, NY 14203.
A JainToshiba Stoke and Vascular Research Center, University at Buffalo (SUNY), Clinical Translational Research Center, 8 floor, 875 Ellicott Street, Buffalo, NY 14203.
D R BednarekToshiba Stoke and Vascular Research Center, University at Buffalo (SUNY), Clinical Translational Research Center, 8 floor, 875 Ellicott Street, Buffalo, NY 14203.
S RudinToshiba Stoke and Vascular Research Center, University at Buffalo (SUNY), Clinical Translational Research Center, 8 floor, 875 Ellicott Street, Buffalo, NY 14203.

Funding

Micro-Radiographic Imager for Neuroovascular InterventionsR01EB002873 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2003 to 2015
$5.6M
NIBIB NIH HHS R01 EB002873
6 · The paper itself

Abstract

Relative object detectability (ROD) quantifies the relative performance of two image detectors for a specified object of interest by taking the following ratio: the integral of detective quantum efficiency of a detector weighted by the frequency spectrum of the object divided by that for a second detector. Four different detectors, namely the micro-angiographic fluoroscope (MAF), the Dexela Model 1207 (Dex) and Hamamatsu Model C10901D-40 (Ham) CMOS x-ray detectors, and a flat-panel detector (FPD) were compared. The ROD was calculated for six pairs of detectors: (1) Dex/FPD, (2) MAF/FPD, (3) Ham/FPD, (4) Dex/Ham, (5) MAF/Ham and (6) MAF/Dex for wires of 5 mm fixed length, solid spheres ranging in diameter from 50 to 600 microns, and four simulated iodine-filled blood vessels of outer diameters 0.4 and 0.5 mm, each with wall thicknesses of 0.1 and 0.15 mm. Marked variation of ROD for the wires and spheres is demonstrated as a function of object size for the various detector pairs. The ROD of all other detectors relative to the FPD was much greater than one for small features and approached 1.0 as the diameter increased. The relative detectability of simulated small iodine-filled blood vessels for all detector pairs was seen to be independent of the vessel wall thickness for the same inner diameter. In this study, the ROD is shown to have the potential to be a useful figure of merit to evaluate the relative performance of two detectors for a given imaging task.

Indexed as

detectabilityDQEnew metricrelative performance of detectorsspecified imaging task

Identifiers

PMID25302002
PMCPMC4188352

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.