Scatter reduction for high resolution image detectors with a region of interest attenuator.
Article in Proceedings of SPIE--the International Society for Optical Engineering, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 citations in OpenAlex.
- Quantitative Assessment of the Effects of Scatter Radiation on Image Quality During Extremity Radiography at a Leading Tertiary Hospital in Ghana: An Experimental Pilot Study.Health science reports · 2026Article
- Incorporating Corrections for the Head-Holder and Compensation Filter when Calculating Skin Dose during Fluoroscopically-Guided Interventions.Proceedings of SPIE--the International Society for Optical Engineering · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
Compton scatter is the main interaction of x-rays with objects undergoing radiographic and fluoroscopic imaging procedures. Such scatter is responsible for reducing image signal to noise ratio which can negatively impact object detection especially for low contrast objects. To reduce scatter, possible methods are smaller fields-of-view, larger air gaps and the use of an anti-scatter grid. Smaller fields of view may not be acceptable and scanned-beam radiography is not practical for real-time imaging. Air gaps can increase geometric unsharpness and thus degrade image resolution. Deployment of an anti-scatter grid is not well suited for high resolution imagers due to the unavailability of high line density grids needed to prevent grid-line artifacts. However, region of interest (ROI) imaging can be used not only for dose reduction but also for scatter reduction in the ROI. The ROI region receives unattenuated x-rays while the peripheral region receives x-rays reduced in intensity by an ROI attenuator. The scatter within the ROI part of the image originates from both the unattenuated ROI and the attenuated peripheral region. The scatter contribution from the periphery is reduced in intensity because of the reduced primary x-rays in that region and the scatter fraction in the ROI is thus reduced. In this study, the scatter fraction for various kVp's, air-gaps and field sizes was measured for a uniform head equivalent phantom. The scatter fraction in the ROI was calculated using a derived scatter fraction formula, which was validated with experimental measurements. It is shown that use of a ROI attenuator can be an effective way to reduce both scatter and patient dose while maintaining the superior image quality of high resolution detectors.