Detector system comparison using relative CNR for specific imaging tasks related to neuro-endovascular image-guided interventions (neuro-EIGIs).

Brendan Loughran, S N Swetadri Vasan, Vivek Singh, Ciprian N Ionita, Amit Jain, Daniel R Bednarek, Stephen Rudin

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Brendan LoughranToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
S N Swetadri VasanToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Vivek SinghToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Ciprian N IonitaToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Amit JainToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Daniel R BednarekToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Stephen RudinToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Toshiba (United States) · US

Funding

Micro-Radiographic Imager for Neuroovascular InterventionsR01EB002873 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2003 to 2015
$5.6M
NIBIB NIH HHS R01 EB002873
6 · The paper itself

Abstract

Neuro-EIGIs require visualization of very small endovascular devices and small vessels. A Microangiographic Fluoroscope (MAF) x-ray detector was developed to improve on the standard flat panel detector's (FPD's) ability to visualize small objects during neuro-EIGIs. To compare the performance of FPD and MAF imaging systems, specific imaging tasks related to those encountered during neuro-EIGIs were used to assess contrast to noise ratio (CNR) of different objects. A bar phantom and a stent were placed at a fixed distance from the x-ray focal spot to mimic a clinical imaging geometry and both objects were imaged by each detector system. Imaging was done without anti-scatter grids and using the same conditions for each system including: the same x-ray beam quality, collimator position, source to imager distance (SID), and source to object distance (SOD). For each object, relative contrasts were found for both imaging systems using the peak and trough signals. The relative noise was found using mean background signal and background noise for varying detector exposures. Next, the CNRs were found for these values for each object imaged and for each imaging system used. A relative CNR metric is defined and used to compare detector imaging performance. The MAF utilizes a temporal filter to reduce the overall image noise. The effects of using this filter with the MAF while imaging the clinical object's CNRs are reported. The relative CNR for the detectors demonstrated that the MAF has superior CNRs for most objects and exposures investigated for this specific imaging task.

Indexed as

angiographyCNRfluoroscopyimage metricsMAFneurovascular interventionsROIx-ray imaging

Identifiers

PMID25301999
PMCPMC4187362
OpenAlexW2020582869

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.