SynthesisInternational orthopaedics2015
Evaluation of the accuracy of patient-specific cutting blocks for total knee arthroplasty: a meta-analysis.
Synthesis in International orthopaedics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
31 citing papers in PubMed, 3 syntheses or guidelines pooled it.
- Comparison of clinical outcomes of VISIONAIRE patient-specific instrumentation with conventional instrumentation in total knee arthroplasty: a systematic literature review and meta-analysis.Archives of orthopaedic and trauma surgery · 2023Pooled it
- Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis.BMC musculoskeletal disorders · 2019Pooled it
- Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2019Pooled it
- The Bony Resection Accuracy with Patient-Specific Instruments during Total Knee Arthroplasty: A Retrospective Case Series Study.BioMed research international · 2021Trial
- A double-blind randomized controlled trial of total knee replacement using patient-specific cutting block instrumentation versus standard instrumentationCanadian journal of surgery. Journal canadien de chirurgie · 2019Trial
- Rotational component alignment in patient-specific total knee arthroplasty compared with conventional cutting instrument.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2019Trial
- Patient-specific Instrumentation Affects Rotational Alignment of the Femoral Component in Total Knee Arthroplasty: A Prospective Randomized Controlled Trial.Orthopaedic surgery · 2019Trial
- Applications and accuracy of 3D-printed surgical guides in traumatology and orthopaedic surgery: A systematic review and meta-analysis.Journal of experimental orthopaedics · 2024Article
- Article
- An overview of 3D printed metal implants in orthopedic applications: Present and future perspectives.Heliyon · 2023Review
- Establishing a New Patient-Specific Implantation Technique for Total Ankle Replacement: An In Vitro Study.Foot & ankle specialist · 2023Article
- Functional gait analysis reveals insufficient hindfoot compensation for varus and valgus osteoarthritis of the knee.International orthopaedics · 2023Article
- Surgeon Dominated Design Can Improve the Accuracy of Patient-Specific Instruments in Kinematically Aligned TKA.Journal of personalized medicine · 2022Article
- Customised, individually made total knee arthroplasty shows promising 1-year clinical and patient reported outcomes.Archives of orthopaedic and trauma surgery · 2021Review
- Patient-Specific Instrumentation Accuracy Evaluated with 3D Virtual Models.Journal of clinical medicine · 2021Article
- High intra- and inter-observer reliability of planning implant size in MRI-based patient-specific instrumentation for total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2021Article
- [Is the unlimited use of surgical instruments safe? : Discussion using the example of endoprosthetics].Der Orthopade · 2020Review
- Accuracy of tibial positioning in the frontal plane: a prospective study comparing conventional and innovative techniques in total knee arthroplasty.Archives of orthopaedic and trauma surgery · 2020Article
- Patient-specific instrumentation improved three-dimensional accuracy in total knee arthroplasty: a comparative radiographic analysis of 1257 total knee arthroplasties.Journal of orthopaedic surgery and research · 2019Article
- Accuracy of patient-specific instrumentation in shoulder arthroplasty: a systematic review and meta-analysis.JSES open access · 2019Review
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeBecause published studies on the accuracy achieved with patient-specific guides during total knee arthroplasty (TKA) contradict each other, this systematic review and meta-analysis sought to compare radiological TKA outcomes when patient-specific cutting blocks (PSCB) were used to the outcomes when standard manual instrumentation was used.
methodsThe meta-analysis was implemented according to PRISMA Statement Criteria. The primary endpoint was the hip-knee-ankle (HKA) angle, which represents the leg's mechanical axis. The accuracy of component placement in the coronal and sagittal planes, and the accuracy of femoral component rotation were also compiled. After testing for publication bias and heterogeneity across studies, data were aggregated random-effects modeling when necessary.
resultsFifteen articles were included: 916 total knee arthroplasty cases in the PSCB group and 998 in the MI group. The mechanical axis did not differ between the two groups (weighted mean difference 0.07°; 95 % CI, -0.5° to 0.65°; p = 0.8). Risk ratio analysis revealed no protective effect of using PSCB relative to the appearance of HKA angle outliers (RR = 0.88; 95 % CI, 0.68-1.13; p = 0.3). There was a trend towards a protective effect with PSCB for the risk of femoral component outliers, but the opposite was observed for the tibial component. The implantation procedure was stopped in 30 cases because the surgeon-authors found excessive discrepancies between the intra-operative observations and the pre-operative plan.
conclusionsThis meta-analysis found no evidence that using patient-specific cutting blocks provides superior accuracy to using manual instrumentation during TKA.
Indexed as
Identifiers
25300397What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.