ArticleAnnals of pediatric cardiology2014
Preliminary evaluation of a microtransesophageal probe in neonates and young infants undergoing surgery for congenital heart disease.
Article in Annals of pediatric cardiology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 14 citations in OpenAlex.
- Recent advances in cardiac anaesthesia.Indian journal of anaesthesia · 2023Article
- A narrative review of modern approach and outcomes evaluation in congenital heart defects.Translational pediatrics · 2021Review
- Microtransesophageal Echocardiographic Guidance during Percutaneous Interatrial Septal Closure without General Anaesthesia.Journal of interventional cardiology · 2020Article
- Feasibility of multiplane microtransoesophageal echocardiographic guidance in structural heart disease transcatheter interventions in adults.Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2017Article
- Utility of a standardized postcardiopulmonary bypass epicardial echocardiography protocol for stage I Norwood palliation.Congenital heart disease · 2017Article
- Micro-transesophageal Echocardiography Guided Mitral Valve Repair After Balloon Dilation for Aortic Valve Stenosis in a Small Infant.Chinese medical journal · 2015Article
- Atrial septal stenting - How I do it?Annals of pediatric cardiologyArticle
- Prospective national audit of major gastrointestinal complications of transesophageal echocardiography studies in children.Annals of cardiac anaesthesiaArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe larger size of the currently available transesophageal echocardiography (TEE) probes limits their use to relatively older infants undergoing cardiac surgery. In very young neonates and infants, epicardial echocardiogram is used to assess postoperative residual defects. Recently, a miniaturized microTEE probe compatible in neonates has been introduced for clinical use. We evaluated the use of this probe in small infants undergoing cardiac surgery. MATERIALS AND
methodsThirty-three consecutive neonates and infants undergoing cardiac surgery at our institution were included in the study. Intraoperative echocardiography with Philips s8-3t microTEE probe done using IE33 platform was utilized to study the preoperative anatomy and assess postoperative results.
resultsThirty-three patients aged 3 days-2 years (mean 5.1 months) and weighing 2.5-11 kg (mean 4.4 kg) underwent perioperative evaluation using the microTEE probe. Good quality two-dimensional and color Doppler images were obtained in all patients. There were no complications related to the probe insertion or manipulation. The findings on microTEE led to revision of surgery in five patients. Certain echocardiographic parameters that could never be recorded with epicardial echocardiogram could be easily seen in microTEE.
conclusionOn preliminary evaluation, the microTEE probe provided good quality images in very small infants who were not amenable for transesophageal echocardiographic evaluation so far. The probe could be used safely in small infants without complications. It appears to be a promising imaging modality in the perioperative assessment of young infants undergoing cardiac surgery, in whom intraoperative epicardial echocardiography is currently the only tool.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.