Evidence map›Paper›PMID 25294536›Full record

ArticleSurgical endoscopy2015

Evaluation of absorbable mesh fixation devices at various deployment angles.

Ahmed M Zihni, Jaime A Cavallo, Dominic M Thompson, Nabeel H Chowdhury, Margaret M Frisella, Brent D Matthews, Corey R Deeken

Abstract readEvaluation Study
In one paragraph

Article in Surgical endoscopy, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ahmed M ZihniDepartment of Surgery, Section of Minimally Invasive Surgery, Washington University School of Medicine, 660 South Euclid Avenue, Campus Box 8109, St. Louis, MO, 63110, USA.
Jaime A Cavallo
Dominic M Thompson
Nabeel H Chowdhury
Margaret M Frisella
Brent D Matthews
Corey R Deeken

Funding

Washington University Center for Cellular ImagingP30CA091842 · NCI · WASHINGTON UNIVERSITY · PI TIMOTHY J. EBERLEIN · 2001 to 2026
$128.0M
Washington University Institute of Clinical and Translational SciencesUL1TR000448 · NCATS · WASHINGTON UNIVERSITY · PI EVANOFF, BRADLEY A · 2012 to 2016
$41.4M
WASHINGTON UNIVERSITY CER MENTORED CAREER DEVELOPMENT AWARD KM1KM1CA156708 · NCI · WASHINGTON UNIVERSITY · PI FRASER, VICTORIA J. · 2010 to 2010
$2.5M
NCATS NIH HHS UL1 TR000448NCATS NIH HHS UL1TR000448NCI NIH HHS KM1 CA156708NCI NIH HHS KM1CA156708NCI NIH HHS P30 CA091842NCI NIH HHS P30CA091842NIMHD NIH HHS L32 MD007472
6 · The paper itself

Abstract

backgroundHernia repair failure may occur due to suboptimal mesh fixation by mechanical constructs before mesh integration. Construct design and acute penetration angle may alter mesh-tissue fixation strength. We compared acute fixation strengths of absorbable fixation devices at various deployment angles, directions of loading, and construct orientations.

methodsPorcine abdominal walls were sectioned. Constructs were deployed at 30°, 45°, 60°, and 90° angles to fix mesh to the tissue specimens. Lap-shear testing was performed in upward, downward, and lateral directions in relation to the abdominal wall cranial-caudal axis to evaluate fixation. Absorbatack™ (AT), SorbaFix™ (SF), and SecureStrap™ in vertical (SSV) and horizontal (SSH) orientations in relation to the abdominal wall cranial-caudal axis were tested. Ten tests were performed for each combination of device, angle, and loading direction. Failure types and strength data were recorded. ANOVA with Tukey-Kramer adjustments for multiple comparisons and χ (2) tests were performed as appropriate (p < 0.05 considered significant).

resultsAt 30°, SSH and SSV had greater fixation strengths (12.95, 12.98 N, respectively) than SF (5.70 N; p = 0.0057, p = 0.0053, respectively). At 45°, mean fixation strength of SSH was significantly greater than SF (18.14, 11.40 N; p = 0.0002). No differences in strength were identified at 60° or 90°. No differences in strength were noted between SSV and SSH with different directions of loading. No differences were noted between SS and AT at any angle. Immediate failure was associated with SF (p < 0.0001) and the 30° tacking angle (p < 0.01).

conclusionsMesh-tissue fixation was stronger at acute deployment angles with SS compared to SF constructs. The 30° angle and the SF device were associated with increased immediate failures. Varying construct and loading direction did not generate statistically significant differences in the fixation strength of absorbable fixation devices in this study.

Indexed as

Surgical MeshAbdominal WallAnimalsBiocompatible MaterialsFemaleHernia, AbdominalHerniorrhaphySwineTensile StrengthBiocompatible Materials

Identifiers

PMID25294536
PMCPMC4390414

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.