SynthesisThe Cochrane database of systematic reviews2014
Fetal pulse oximetry for fetal assessment in labour.
Synthesis in The Cochrane database of systematic reviews, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers, 6 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
29 citing papers in PubMed, 6 syntheses or guidelines pooled it, 212 citations in OpenAlex.
- Association between intrapartum fetal pulse oximetry and adverse perinatal and long-term outcomes: A systematic review and meta-analysis.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2025Pooled it
- Effectiveness of intrapartum fetal surveillance to improve maternal and neonatal outcomes: a systematic review and network meta-analysis.CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne · 2021Pooled it
- Antenatal and intrapartum interventions for preventing cerebral palsy: an overview of Cochrane systematic reviews.The Cochrane database of systematic reviews · 2017Pooled it
- Intermittent auscultation (IA) of fetal heart rate in labour for fetal well-being.The Cochrane database of systematic reviews · 2017Pooled it
- Fetal movement counting for assessment of fetal wellbeing.The Cochrane database of systematic reviews · 2015Pooled it
- Reducing stillbirths: screening and monitoring during pregnancy and labour.BMC pregnancy and childbirth · 2009Pooled it
- Protocol for a randomised controlled trial of fetal scalp blood lactate measurement to reduce caesarean sections during labour: the Flamingo trial [ACTRN12611000172909].BMC pregnancy and childbirth · 2015Trial
- FOSTER: A Comprehensive Pipeline for Transabdominal Fetal Pulse Oximetry Validated in a Large Animal Model of Pregnancy.IEEE transactions on bio-medical engineering · 2026Article
- Feasibility and safety of intrapartum foetal pulse oximetry using a disposable scalp probe: a cross-sectional study.BMC pregnancy and childbirth · 2026Article
- A filamentary soft robotic probe for multimodal in utero monitoring of fetal health.Nature biomedical engineering · 2026Article
- Correlation of suspicious and pathological cardiotocography with umbilical cord blood gas parameters: A prospective cohort study.Journal of family medicine and primary care · 2025Article
- Development and Characterisation of a Microneedle Sensor for Intrapartum Fetal Monitoring.Biosensors · 2025Article
- Preclinical development of a continuous fetal lactate biosensor to detect acidosis.Pregnancy (Hoboken, N.J.) · 2025Article
- Pulse oximetry in pediatric care: Balancing advantages and limitations.World journal of clinical pediatrics · 2024Article
- Transcutaneous Discrimination of Fetal Heart Rate from Maternal Heart Rate: A Fetal Oximetry Proof-of-Concept.Reproductive sciences (Thousand Oaks, Calif.) · 2024Article
- Perinatal and Neonatal Outcomes Using Cardiotocography Versus STAN and Cardiotocography: a Systematic Review.Maedica · 2023Article
- Recovering fetal signals transabdominally through interferometric near-infrared spectroscopy (iNIRS).Biomedical optics express · 2023Article
- Association between intrapartum fetal pulse oximetry and adverse perinatal and long-term outcomes: a systematic review and meta-analysis protocol.HRB open research · 2023Article
- A Review on Magnetic Induction Spectroscopy Potential for Fetal Acidosis Examination.Sensors (Basel, Switzerland) · 2022Review
- A review of fetal cardiac monitoring, with a focus on low- and middle-income countries.Physiological measurement · 2020Review
Corrections and comments
- Update of
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe use of conventional cardiotocographic (CTG) monitoring of fetal well-being during labour is associated with an increased caesarean section rate, compared with intermittent auscultation of the fetal heart rate, resulting in a reduction in neonatal seizures, although no differences in other neonatal outcomes. To improve the sensitivity of this test and therefore reduce the number of caesarean sections performed for nonreassuring fetal status, several additional measures of evaluating fetal well-being have been considered. These have demonstrated some effect on reducing caesarean section rates, for example, fetal scalp blood sampling for pH estimation/lactate measurement. The adaptation of pulse oximetry for use in the unborn fetus could potentially contribute to improved evaluation during labour and therefore lead to a reduction in caesarean sections for nonreassuring fetal status, without any change in neonatal outcomes.
objectivesTo compare the effectiveness and safety of fetal intrapartum pulse oximetry with other surveillance techniques. SEARCH
methodsWe searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 May 2014), contacted experts in the field and searched reference lists of retrieved studies. In previous versions of this review, we performed additional searches of MEDLINE, Embase and Current Contents. These searches were discontinued for this review update, as they consistently failed to identify any trials that were not shown in the Cochrane Pregnancy and Childbirth Group's Trials Register. SELECTION CRITERIA: All published and unpublished randomised controlled trials that compared maternal and fetal outcomes when fetal pulse oximetry was used in labour, (i) with or without concurrent use of conventional fetal surveillance, that is, cardiotocography (CTG), compared with using CTG alone or (ii) with or without concurrent use of both CTG and other method(s) of fetal surveillance, such as fetal electrocardiography (ECG) plus CTG. DATA COLLECTION AND ANALYSIS: At least two independent review authors performed data extraction. We sought additional information from the investigators of three of the reported trials. MAIN
resultsWe included seven published trials: six comparing fetal pulse oximetry and CTG with CTG alone (or when fetal pulse oximetry values were blinded) and one comparing fetal pulse oximetry plus CTG with fetal ECG plus CTG. The published trials, with some unpublished data, were at high risk of bias in terms of the impractical nature of blinding participants and clinicians, as well as high risk or unclear risk of bias for outcome assessor for all but one report. Selection bias, attrition bias, reporting bias and other sources of bias were of low or unclear risk. The trials reported on a total of 8013 pregnancies. Differing entry criteria necessitated separate analyses, rather than meta-analysis of all trials.Systematic review of four trials from 34 weeks not requiring fetal blood sampling (FBS) prior to study entry showed no evidence of differences in the overall caesarean section rate between those monitored with fetal oximetry and those not monitored with fetal pulse oximetry or for whom the fetal pulse oximetry results were masked (average risk ratio (RR) 0.99 using random-effects, 95% confidence intervals (CI) 0.86 to 1.13, n = 4008, I² = 45%). There was evidence of a higher risk of caesarean section in the group with fetal oximetry plus CTG than in the group with fetal ECG plus CTG (one study, n = 180, RR 1.56, 95% CI 1.06 to 2.29). Neonatal seizures and neonatal encephalopathy were rare in both groups. No studies reported details of long-term disability.There was evidence of a decrease in caesarean section for nonreassuring fetal status in the fetal pulse oximetry plus CTG group compared to the CTG group, gestation from 34 weeks (average RR (random-effects) 0.65, 95% CI 0.46 to 0.90, n = 4008, I² = 63%). There was no evidence of differences between groups in caesarean section for dystocia, although the overall incidence rates varied between the trials. AUTHORS'
conclusionsThe addition of fetal pulse oximetry does not reduce overall caesarean section rates. One study found a higher caesarean section rate in the group monitored with fetal pulse oximetry plus CTG, compared with fetal ECG plus CTG. The data provide limited support for the use of fetal pulse oximetry when used in the presence of a nonreassuring CTG, to reduce caesarean section for nonreassuring fetal status. A better method than pulse oximetry is required to enhance the overall evaluation of fetal well-being in labour.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.