Evidence map›Paper›PMID 25281982›Full record

ArticleMedical physics2014

Vaporization dynamics of volatile perfluorocarbon droplets: a theoretical model and in vitro validation.

Alexander A Doinikov, Paul S Sheeran, Ayache Bouakaz, Paul A Dayton

Open access · bronzeAbstract readValidation Study
In one paragraph

Article in Medical physics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 60 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Nested Nanobubbles for Ultrasound-Triggered Drug Release.ACS applied materials & interfaces · 2020
    Article
  13. Review
  14. Article
  15. Methods of Generating Submicrometer Phase-Shift Perfluorocarbon Droplets for Applications in Medical Ultrasonography.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2017
    Article
  16. Article
  17. Dual-frequency acoustic droplet vaporization detection for medical imaging.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2015
    Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Alexander A DoinikovInserm U930, Université François Rabelais, Tours 37044, France.
Paul S SheeranJoint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, North Carolina 27599.
Ayache BouakazInserm U930, Université François Rabelais, Tours 37044, France.
Paul A DaytonJoint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, North Carolina 27599.
North Carolina State University · USUniversité de Tours · FR

Funding

Precision engineering of ultrasonically-targeted drug delivery vehiclesR01EB008733 · NIBIB · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI DAYTON, PAUL A · 2009 to 2012
$1.3M
PiV Ultra 12 - 24 Ultra High Speed Camera for Ultrasound Microbubble ResearchS10RR025594 · NCRR · UNIVERSITY OF VIRGINIA · PI HOSSACK, JOHN A · 2009 to 2009
$499k
NCRR NIH HHS S10 RR025594NIBIB NIH HHS EB-008733NIBIB NIH HHS R01 EB008733
6 · The paper itself

Abstract

purposePerfluorocarbon (PFC) microdroplets, called phase-change contrast agents (PCCAs), are a promising tool in ultrasound imaging and therapy. Interest in PCCAs is motivated by the fact that they can be triggered to transition from the liquid state to the gas state by an externally applied acoustic pulse. This property opens up new approaches to applications in ultrasound medicine. Insight into the physics of vaporization of PFC droplets is vital for effective use of PCCAs and for anticipating bioeffects. PCCAs composed of volatile PFCs (with low boiling point) exhibit complex dynamic behavior: after vaporization by a short acoustic pulse, a PFC droplet turns into a vapor bubble which undergoes overexpansion and damped radial oscillation until settling to a final diameter. This behavior has not been well described theoretically so far. The purpose of our study is to develop an improved theoretical model that describes the vaporization dynamics of volatile PFC droplets and to validate this model by comparison with in vitro experimental data.

methodsThe derivation of the model is based on applying the mathematical methods of fluid dynamics and thermodynamics to the process of the acoustic vaporization of PFC droplets. The used approach corrects shortcomings of the existing models. The validation of the model is carried out by comparing simulated results with in vitro experimental data acquired by ultrahigh speed video microscopy for octafluoropropane (OFP) and decafluorobutane (DFB) microdroplets of different sizes.

resultsThe developed theory allows one to simulate the growth of a vapor bubble inside a PFC droplet until the liquid PFC is completely converted into vapor, and the subsequent overexpansion and damped oscillations of the vapor bubble, including the influence of an externally applied acoustic pulse. To evaluate quantitatively the difference between simulated and experimental results, the L2-norm errors were calculated for all cases where the simulated and experimental results are compared. These errors were found to be in the ranges of 0.043-0.067 and 0.037-0.088 for OFP and DFB droplets, respectively. These values allow one to consider agreement between the simulated and experimental results as good. This agreement is attained by varying only 2 of 16 model parameters which describe the material properties of gaseous and liquid PFCs and the liquid surrounding the PFC droplet. The fitting parameters are the viscosity and the surface tension of the surrounding liquid. All other model parameters are kept invariable.

conclusionsThe good agreement between the theoretical and experimental results suggests that the developed model is able to correctly describe the key physical processes underlying the vaporization dynamics of volatile PFC droplets. The necessity of varying the parameters of the surrounding liquid for fitting the experimental curves can be explained by the fact that the parts of the initial phospholipid shell of PFC droplets remain on the surface of vapor bubbles at the oscillatory stage and their presence affects the bubble dynamics.

Indexed as

Models, TheoreticalAcousticsAcoustic StimulationAlgorithmsComputer SimulationContrast MediaFluorocarbonsGasesHydrodynamicsMicrofluidicsMicroscopy, VideoThermodynamicsVolatilizationContrast MediaFluorocarbonsGasesperfluorobutaneperflutren

Identifiers

PMID25281982
PMCPMC4290562
OpenAlexW2052615661

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.