ArticleMedical physics2014
A system to use electromagnetic tracking for the quality assurance of brachytherapy catheter digitization.
Article in Medical physics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed.
- Implant geometry as a patient-specific identifier in breast brachytherapy: leveraging electromagnetic tracking to prevent treatment mix-ups.Technical innovations & patient support in radiation oncology · 2026Article
- Integrating automated electromagnetic tracking-based needle reconstruction in the intraoperative high-dose-rate prostate brachytherapy workflow.Physics and imaging in radiation oncology · 2025Article
- Electromagnetic tracking for integrated quality assurance in breast interstitial brachytherapy: The impact of registration method.Journal of contemporary brachytherapy · 2024Article
- A scintillation dosimeter with real-time positional tracking information for in vivo dosimetry error detection in HDR brachytherapy.Journal of applied clinical medical physics · 2023Article
- A review of brachytherapy physical phantoms developed over the last 20 years: clinical purpose and future requirements.Journal of contemporary brachytherapy · 2021Review
- Automatic segmentation and applicator reconstruction for CT-based brachytherapy of cervical cancer using 3D convolutional neural networks.Journal of applied clinical medical physics · 2020Article
- Review
- Improved electromagnetic tracking for catheter path reconstruction with application in high-dose-rate brachytherapy.International journal of computer assisted radiology and surgery · 2017Article
- A tool to automatically analyze electromagnetic tracking data from high dose rate brachytherapy of breast cancer patients.PloS one · 2017Article
- Electromagnetic tracking (EMT) technology for improved treatment quality assurance in interstitial brachytherapy.Journal of applied clinical medical physics · 2017Article
- Electromagnetic tracking for treatment verification in interstitial brachytherapy.Journal of contemporary brachytherapy · 2016Review
- Design and Fabrication of MR-Tracked Metallic Stylet for Gynecologic Brachytherapy.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2016Article
- Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy.Medical physics · 2015Article
- Magnetic resonance imaging-guided brachytherapy for cervical cancer: initiating a program.Journal of contemporary brachytherapy · 2015Review
- Review of advanced catheter technologies in radiation oncology brachytherapy procedures.Cancer management and research · 2015Review
- Review of strategies for MRI based reconstruction of endocavitary and interstitial applicators in brachytherapy of cervical cancer.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation OncologyReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
purposeTo investigate the use of a system using electromagnetic tracking (EMT), post-processing and an error-detection algorithm for detecting errors and resolving uncertainties in high-dose-rate brachytherapy catheter digitization for treatment planning.
methodsEMT was used to localize 15 catheters inserted into a phantom using a stepwise acquisition technique. Five distinct acquisition experiments were performed. Noise associated with the acquisition was calculated. The dwell location configuration was extracted from the EMT data. A CT scan of the phantom was performed, and five distinct catheter digitization sessions were performed. No a priori registration of the CT scan coordinate system with the EMT coordinate system was performed. CT-based digitization was automatically extracted from the brachytherapy plan DICOM files (CT), and rigid registration was performed between EMT and CT dwell positions. EMT registration error was characterized in terms of the mean and maximum distance between corresponding EMT and CT dwell positions per catheter. An algorithm for error detection and identification was presented. Three types of errors were systematically simulated: swap of two catheter numbers, partial swap of catheter number identification for parts of the catheters (mix), and catheter-tip shift. Error-detection sensitivity (number of simulated scenarios correctly identified as containing an error/number of simulated scenarios containing an error) and specificity (number of scenarios correctly identified as not containing errors/number of correct scenarios) were calculated. Catheter identification sensitivity (number of catheters correctly identified as erroneous across all scenarios/number of erroneous catheters across all scenarios) and specificity (number of catheters correctly identified as correct across all scenarios/number of correct catheters across all scenarios) were calculated. The mean detected and identified shift was calculated.
resultsThe maximum noise ±1 standard deviation associated with the EMT acquisitions was 1.0 ± 0.1 mm, and the mean noise was 0.6 ± 0.1 mm. Registration of all the EMT and CT dwell positions was associated with a mean catheter error of 0.6 ± 0.2 mm, a maximum catheter error of 0.9 ± 0.4 mm, a mean dwell error of 1.0 ± 0.3 mm, and a maximum dwell error of 1.3 ± 0.7 mm. Error detection and catheter identification sensitivity and specificity of 100% were observed for swap, mix and shift (≥2.6 mm for error detection; ≥2.7 mm for catheter identification) errors. A mean detected shift of 1.8 ± 0.4 mm and a mean identified shift of 1.9 ± 0.4 mm were observed.
conclusionsRegistration of the EMT dwell positions to the CT dwell positions was possible with a residual mean error per catheter of 0.6 ± 0.2 mm and a maximum error for any dwell of 1.3 ± 0.7 mm. These low residual registration errors show that quality assurance of the general characteristics of the catheters and of possible errors affecting one specific dwell position is possible. The sensitivity and specificity of the catheter digitization verification algorithm was 100% for swap and mix errors and for shifts ≥2.6 mm. On average, shifts ≥1.8 mm were detected, and shifts ≥1.9 mm were detected and identified.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials