Evidence map›Paper›PMID 25273671›Full record

ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2015

Myocardial perfusion imaging determination using an appropriate use smartphone application.

Ashish Mahajan, Susan Bal, Harvey Hahn

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 7 citations in OpenAlex.

  1. Pooled it
  2. Outcomes after inappropriate nuclear myocardial perfusion imaging: A meta-analysis.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016
    Review
  3. Review of Cardiovascular Imaging in the Journal of Nuclear Cardiology in 2015-Part 2 of 2: Myocardial perfusion imaging.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016
    Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Ashish MahajanDepartment of Internal Medicine, Kettering Medical Center, 3535 Southern Boulevard, Kettering, OH, 45429, USA. mahajan_82@yahoo.com
Susan Bal
Harvey Hahn
Kettering Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInappropriate cardiac imaging has been a significant cost concern and cause of radiation burden to patients.

objectiveTo assess if a smartphone application (app) based on 2009 Appropriate Use Criteria (AUC) for Cardiac Radionuclide Imaging published by American College of Cardiology would be feasible at the point of order.

methodsWe evaluated stress myocardial perfusion imaging (MPI) (N = 403) (mean age = 62.23 years; 47.89% males) over a 4 month period using a smartphone app to determine whether the study ordered was Appropriate, Inappropriate, or Uncertain per 2009 AUC. We also monitored the time needed to use the app to determine the level of appropriateness of each stress MPI. The results of the stress MPI were noted.

resultsOf the 403 stress MPIs evaluated, 267 (66.25%) were noted to be Appropriate, 118 (29.28%) were Inappropriate, and 13 (3.23%) were Uncertain, per AUC; 5 (1.25%) remained unclassified. Average time needed to use the app to assess each stress MPI for appropriateness was noted to be 44 (±9) seconds. Non-teaching physicians ordered 70 (38.89%) inappropriate stress MPIs as compared to 20 (23.53%) ordered by physicians on resident teaching service, and 28 (23.33%) by cardiologists (P = .0045). Among inappropriately ordered stress MPIs, 87 (42.65%) were ordered in females as compared to 31 (17.13%) in males (P < .0001). 70 (26.22%) stress MPIs among appropriately ordered were abnormal (reversible ischemia or fixed perfusion defect) as compared to 15 (12.17%) among inappropriately ordered stress MPIs (P = .0032).

conclusionA free and convenient smartphone app provides an easy-to-use tool to assist physicians in determining the level of appropriateness of stress MPI in a time- and cost-effective manner at the point of order. The smartphone app may have potential to promote the usage of the AUC and possibly aid reduction of healthcare cost and ionizing radiation burden.

Indexed as

Health Services MisuseMobile ApplicationsMyocardial Perfusion ImagingSmartphoneAgedCardiologyCoronary Artery DiseaseFemaleHumansMaleMiddle AgedRadionuclide ImagingTomography, Emission-Computed, Single-Photon

Identifiers

PMID25273671
OpenAlexW2168650758

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.